Page 15
509 Sharptown Road P.O. Box 345 Bridgeport, NJ 08014
Email: [email protected] Fax: 856-467-5511
Internet: http://caddycorp.com Phone: 856-467-4222
Steam Trap Maintenance
(optional feature)
Operating and Installation
1.
Steam trap works automatically while system is operating.
2.
Steam trap must be blown down every six months.
3.
Steam trap must be dismantled and checked every year.
4.
Blow down procedure:
a.
Shutoff steam purging system. (Valves located in raceway).
NOTE
Shutting down steam supply and steam return line is not necessary, cooking operation may continue.
b.
Unbolt screen holder, Part #12, located on bottom of steam trap. (See steam trap diagram
on Page 23)
c.
Remove screen, Part #10, check for deformation, blockage and damage.
d.
Open shut-off value located on steam supply manifold for approximately ten seconds. This will
allow sediment trapped inside screen and manifold to be discharged.
e.
Replace screen and screen holder.
f.
Open both steam purging system shut-off valves.
5.
How to dismantle and check steam trap.
a.
Shut-off steam purging system (valves located in raceway).
NOTE: Shutting down steam lines is not necessary, cooking operation may continue.
b.
Unbolt the four bolts, Part #13, and remove the Cover #2 from the case, Part #1, check the gasket,
Part #8, for deformation and damage.