background image

 

 

3

 

Warranty and liability 

The warranty period of the charging station is specified by the official Cabur’s selling conditions. 

 

 
This operating manual serves to ensure fault-free and safe use of the product; compliance with 
its content is a prerequisite for the fulfilment of any warranty claims.  
 
Excluded from the warranty are such defects that result from any arrangement and assembly 
not  effected  by  the  producer,  insufficient  equipment,  failure  to  observe  the  installation 
requirements and conditions of use, excessive load on the components beyond the capacities 
specified  by  the  seller,  negligent  or  incorrect  handling  and  use  of  unsuitable  operating 
materials.  
 
This also applies to defects that are attributable to material provided by the user. 
 
In particular, claims for damages expire in the event of: 

 

Inappropriate use 

 

Modifications or additions  

 

Repairs carried out improperly 

 

Disasters, foreign body impact and force majeure  

 
The producer is also not liable for damage caused by the actions of third parties, atmospheric 
discharges, overvoltage and events related to chemical influences.  
 
The warranty does not apply to the replacement of parts that are subject to natural wear and 
tear. 
 
 

4

 

Limits of use 

This charger is an electrical equipment designed for charging battery electric vehicles (BEV).  
 
The plug and the socket compliant to EN 62196 (alternating current charging, MODE 3) are used 
for charging BEVs.  
 
The charger is suitable for indoor and outdoor usage. The product is built according to the state 
of the art and the generally accepted safety regulations. Nevertheless, during its use hazards to 
life and limb of the operator or third parties may occur or the product and other material assets 
may  be  negatively  affected.  Intended  use  includes  observing  the  operating  manual  and 
compliance with the maintenance requirements.  
 
Only use the product if it is in technically perfect condition. Use the product as intended and in 
a safe way.  
 
In  case  of  malfunctions  or  damages  that  could  impact  safety  please  contact  a  qualified 
technician and inform the producer. 
 

Summary of Contents for EV EASY Series

Page 1: ...Cabur EASY EV Smart Chargers Installation and operating manual...

Page 2: ...3 Installation of the protection against short circuit 10 6 4 Installation of the protection against residual current 10 6 5 Overvoltage protection 11 6 6 Installation cables 11 6 7 Supported power su...

Page 3: ...2 Markings Point of contact under Directive 2014 35 EU Cabur S r L Localit Isola Grande 45 17041 Altare SV Italy www cabur it...

Page 4: ...07 2021 Cabur Technical Office New name Cabur_EV_EASY_Installation_Instruction_Manual 1 1 19 07 2021 Cabur Technical Office Updated cover Chapters 2 3 4 revised 1 2 20 11 2021 Cabur Technical Office...

Page 5: ...roduct whenever needed The reproduction of this manual is not allowed without the written authorization by Cabur s r l 2 1 2 About safety The product conforms with the state of the art and the applica...

Page 6: ...charger It is prohibited to reconfigure or modify the product The product may only be operated in perfect conditions 2 1 3 About maintenance Do not open the charger Do not touch the electronic parts...

Page 7: ...he producer is also not liable for damage caused by the actions of third parties atmospheric discharges overvoltage and events related to chemical influences The warranty does not apply to the replace...

Page 8: ...ted under the operating conditions specified in the documentation This documentation is mandatorily to be read by qualified personnel for installation and initial operation as well as by the user for...

Page 9: ...V0 PC ASA UL94 V0 Cooling system Integrated fan Integrated fan Mounting Wall Stand Wall Stand Electrical Data Mains Voltage 400V 15 three phase 230 V 15 single phase 400V 15 three phase 230 V 15 sing...

Page 10: ...tion CP fault protection Relay adhesion protection IP Degree IP54 IP54 Ambient Temperature 25 C to 50 C 25 C to 50 C Operating Humidity 95 RH 95 RH Certificates Standards IEC 61851 1 2017 RED WiFi 2 4...

Page 11: ...he wall The anti theft stainless screw provided with the charger 6 3 Installation of the protection against short circuit The charger itself has an overcurrent protection integrated function Neverthel...

Page 12: ...r the safety and the state of the art of the electrical installations 6 7 Supported power supply systems Both single phase and three phase chargers support the following power supply systems TN S TN C...

Page 13: ...ached to the charger rear side one rubber gland for the input cable 2 Lean the mounting template against the wall The height from the centre of the template to the ground should be determined accordin...

Page 14: ...Fix the wall mount bracket on the wall with the expansion screws 5 Hang the charger on the wall mounted bracket This is done just sliding from top to bottom the charger into the bracket binaries Then...

Page 15: ...o avoid the cable from being pulled by external forces or you can add a cable fixing device which stabilize the input cable 9 Close the wire cover and screw up the wire cover with 4 screws 10 Close th...

Page 16: ...poured platform shall be not less than 150mm while the exposed length is recommended to be in the range from 15 to 30mm The power cables arriving through the PVC conduit shall be pulled out not less...

Page 17: ...Then remove the four M6x20 bolts on the stand hanging plate Finally align the holes of the two metal plates and fix them using the M6x20 bolts 6 Hang the charger on the stand just sliding it bottom s...

Page 18: ...hould be noted that there is no device for fixing the input cable so you must leave enough space for the cable to avoid the cable from being pulled by external forces or you can add a cable fixing dev...

Page 19: ...used in the EASY model None All around the charger LED indicator A LED belt is placed all around the charger and assumes different colours to indicate the current status see table below LED Belt Colou...

Page 20: ...9 1 1 WiFi AP mode The WiFi AP Access Point mode also referred as Hot Spot is mainly used for configuration and monitoring purposes In this mode the charger creates a WiFi network with a specified SS...

Page 21: ...can for available WiFi networks with the connecting device utility 2 Connect the device PC Tablet Smartphone to the WiFi network generated by the charger it should have an SSID name similar to ACPILE_...

Page 22: ...The configuration is performed by means of a web app which connects to the charger internal web server Please consider the following instructions to properly use the app for configuration Step No Des...

Page 23: ...with its label Standby means the charger is not charging 3 Charger state button Pressing this button the user can access the charger state page to monitor all the parameters of the charger and their s...

Page 24: ...user is now allowed to see the configuration main pages From this page the user can access other pages by clicking the 6 buttons at the top of the page These buttons will be explained later in the do...

Page 25: ...p No Description Picture 5 Clicking on the Setting button a new setting page is presented with the following menus System time Important note these parameters shall be configured by qualified personne...

Page 26: ...25 Step No Description Picture 6 Clicking on the History button the user can access the historical logs of the device 7 Clicking on the Report button the user can access the reports of the device...

Page 27: ...6 Step No Description Picture 8 Clicking on the Upgrade button the user can upgrade the system see chapter 10 for details Important note these parameters shall be configured by qualified personnel onl...

Page 28: ...time can be set The correct time is automatically read from the connecting device and is shown in the Current time field Clicking the Confirm button the time setting is saved as the charger time Impo...

Page 29: ...n the other side In the CASE C mode integrated cable connect the cable to the EV The charging process starts automatically after connecting to the EV inlet When the charging process starts the LED bel...

Page 30: ...ce PC tablet smartphone is connected to the charger WiFi AP Open the internet browser Connect to the following URL http 192 168 1 1 The home page of the web app is shown 2 Clicking on the Configuratio...

Page 31: ...upgrade file provided by the manufacturer it is typically a file named as name_of_the_upgrade_file bin This file can be eventually downloaded directly from the manufacturer website or requested direct...

Page 32: ...ted by the check_sum_tool shall be copied in the Upgrade file checksum field The Continue button shall be clicked after that 8 The upgrade process starts and will last more or less 15 sec At the end o...

Page 33: ...possible to have name_of_the_upgrade_file _IT bin IT italian language name_of_the_upgrade_file _EN bin EN english language name_of_the_upgrade_file _DE bin DE german language name_of_the_upgrade_file...

Reviews: