Configuration Commands
80-10200000-01
4–19
4.5.6.3 Leased Circuit Failures menu
Determines which criteria are used for determining DLC failure.
A) DATA LOSS
A) ENABLED
Monitors DLC Received data for
activity.
B) DISABLED (F)
Not monitored.
C) DATA LOSS
TIMER
Time over which loss of data
needs to occur to sense DLC loss.
B) CLOCK LOSS
A) ENABLED
Monitors DLC clock for activity.
B) DISABLED (F)
Not monitored.
C) CLOCK LOSS
TIMER
Time over which there must be a
good clock for restoral purposes.
C) I/DSR LOSS
A) ENABLED
Monitors DLC I (X.21) or DSR
(V.35) for activity.
B) DISABLED (F)
Not monitored.
C) I/DSR LOSS
TIMER
Time over which loss of I or DSR
needs to occur to sense DLC loss.