Configuration Commands
80-10200000-01
4–11
J) ALERT B-CHANNEL USAGE
A) ENABLED (F)
Sends an ALERT indicating how
many ‘B’ channels are in use. The
ALERT message is:
ALERT B-Channel usage x,y
Where x and y are numerals in the
range 0 - 2 and :-
x is the number of channels in use
and y is the number of channels
remaining available.
x + y = 2.
B) DISABLED
This ALERT is disabled.
K) ALERT SYSTEM
A) ENABLED (F)
Sends an alert indicating that a call
attempt failed due to an insufficient
number of ‘B’-Channels being
available. The alert message is:
ALERT Insufficient B-
Channels
B) DISABLED
Sends an ALERT indicating system
states:
ALERT System 0 Bank A
When the unit has booted from
Bank A Flash.
ALERT System 0 Bank B
When the unit has booted from
Bank B Flash.
ALERT System 1
When the NVRAM has been
defaulted, due to the NVRAM being
corrupted, reset, or a request for it
to be restored.