USING BRIDGE MANAGEMENT OPTIONS
5-12
Figure 5-3
b. Port Setup Screen - DSX-1 Module Installed
The DSX-1 SETUP command leads to the DSX-1 port setup screen.
If only one SPIM is installed in a DSX-1 equipped NB30, the information
on the right side of Figure 5-3 b, including the redundancy EXECUTE
option, will not appear.
5.1.4.1
Port Setup Screen Fields
V.35/RS449 Config A-1: Rem DM Enable
Indicates whether the bridge will ignore or recognize the Data Mode
Control Signal from the Data Circuit Terminating Equipment (DCE). The
Data Mode Control Signal is set by switching the Data Mode Control
Switch on the back panel of the NB30. (See the NB30 Ethernet Bridge
User's Manual for more information.)
OFF means that the NB30 will force Data Mode true and ignore the Data
Mode Control Signal from the DCE.
ON means that the NB30 will require the Data Mode Control Signal from
the DCE.
3/20/91 PORT SETUP
Network Address: 00-00-1D-00-10-CA Type: NB30
Bridge Name: CABLETRON REMOTE BRIDGE SW Version: 1.10.00
Location: LOCAL HW Version: 1
Uptime: 01 Days 01 Hours 33 Minutes Status: ON_LINE
Config A-1: T1 Timing Mode MASTER Default Enet Port: Port 1
Config A-2: STA enable OFF Active Enet Port: Port 1
Config A-3: T1 Framing ESF Enable Redundancy: NO
Config A-4: Unused OFF Port 1 Poll Address: 00-00-00-00-00-00
Port 1 Poll Interval: 2
Comm Port Mode: RS-422 Port 1 Max Retries: 2
Root Switch: OFF Port 2 Poll Address: 00-00-00-00-00-00
Port 2 Poll Interval: 2
Fwd Broadcast Switch: OFF Port 2 Max Retries: 2
RETURN DSX-1 SETUP EXECUTE
Summary of Contents for NB30
Page 2: ......
Page 4: ...NOTICE ii ...
Page 10: ...INTRODUCTION 1 4 ...
Page 20: ...USING LOCAL MANAGEMENT 3 4 ...
Page 30: ...BRIDGE INFORMATION SCREEN 4 10 ...
Page 78: ...USING BRIDGE MANAGEMENT OPTIONS 5 48 Table 5 1 Optimal Bridge Max Age Parameters ...
Page 84: ...USING BRIDGE MANAGEMENT OPTIONS 5 54 ...
Page 88: ...Appendix A A 4 ...