MMAC-M5FNB SETUP
Page 3-7
MMAC-M5PSMs are installed, the load is evenly distributed; if one
power supply fails for any reason other than a shorted DC backplane,
the second power supply assumes the load.
Note: The power requirements of some FDDI configurations require
dual power supplies.
The MMAC-M5FNB power supply modules must be installed in the
rightmost and leftmost slots of the chassis (Figure 3-4). If you intend
to install a single MMAC-M5PSM, install it in the rightmost slot; the
far left slot is then available for an optional fifth MIM.
Figure 3-4. Module Installation Diagram for the M5FNB
MMAC-M5FNB
The Complete Networking Solution™
Multi Media Access Center
1
2
3
4
5
1.) Power supply module (required)
2.) Management module
3.) MIM slots
4.) Optional MIM slot (without redundant power supply)
5.) Optional redundant power supply module