background image

CL.FWS CONTROL UNIT

1) DESCRIPTION

The CL.FWS control unit is able to control 1 electro-mechanical tubular motor for sun shade curtains and 
rolling shutters.
The control unit incorporates the functions for sun control and protection is case of excessive wind or rain.

2) ACCESSORIES

The control unit can be equipped with the following accessories:

CL.WL:

 combined sensor: wind and light.

CL.WLR:

 combined sensor: wind, light and rain.

RR.FWS: 

extractable radio receiver, 433.92 MHz.

T4WV-C: 

4-channel, rolling code transmitter (

DO NOT USE T2WV-C

).

3) WIRE DIAGRAM

Terminal

Function

Description

L,N

Phase, Neutral

Control unit power supply, 230VAC 50Hz

M

Motor control

Motor opening/closing controls:

- COM: command, common;
- Op: OPEN contact;
- Cl: CLOSE contact.

Use auto-default push buttons only.

JM1

Rain sensor

Rain sensor connection:

- a: sensors, common;
- b: rain signal;
- c: positive, 12V.

JM2

Sun sensor

Sun sensor connection:

- d: sun signal.
- e: sensors, common;

JM3

Wind sensor

Wind sensor connection:

- f: wind signal;
- g: sensors, common.

RADIO

Extractable radio module

RR.FWS item

ANT

Integrated antenna

Used with RR.FWS item

MOT

Motor connection

Motor contacts:

- COM: motor, common;
- Op: OPEN motor contact;
- Cl: CLOSE motor contact.

4) SENSOR MANAGEMENT

If the control unit is connected with sensors for the management of weather agents, the system works as 
follows:

Wind sensor: 

connect the sensor (anemometer) to the preset input (see diagram) and set the desired wind 

speed by using the TR2 trimmer (see section “TRIMMER FUNCTIONS”). 
During the entire period of wind alarm and the following 8 minutes, the curtain cannot be operated by means 
of the push-buttons. When this time has elapsed, the controls are reset automatically.

Rain sensor:

 when the rain sensor triggers, a closing control signal (see SW2) is sent and remains activated 

for 8 minutes, thus excluding any other command.

Sun sensor:

 the sensor checks the light present and, if the preset threshold is overcome, through TR1 

trimmer (see section “trimmer function”), a period of 2 minutes should elapse before the control unit sends 
an opening control signal of the sun shade curtain. The reverse procedure is carried out when the detected 
light goes under the preset threshold (in this case, after 15 minutes, a closing control signal is sent of the 
sun shade curtain).
Both thresholds should be kept for the entire time necessary to control the movement.

Summary of Contents for CL.FWS

Page 1: ...CENTRALE DI COMANDO CONTROL UNIT CENTRALE DE COMMANDE CENTRAL DE MANDO CL FWS Manuale istruzioni Operating instructions Livret d instructions Manual de instrucciones...

Page 2: ...5 Klux 55 Klux 75 Klux 99 Klux 40 Km h 25 Km h 15 Km h 5 Km h ANT ON 1 4 SW TR1 TR2 L2 L1 1 2 3 4 5 6 7 8 9 10 11 12 a b c d e f g LE3 PL1 RADIO PL2 L N Op COM COM Cl Op Cl 230Vac 50Hz CL FWS a COM b...

Page 3: ...CL FWS CL WLR 8 9 10 11 12 5 4 3 2 1 1 2 3 4 5...

Page 4: ...scrizioni e le illustrazioni presenti in questo manuale non sono impegnative Lasciando inal terate le caratteristiche essenziali del prodotto il fabbricante si riserva il diritto di apportare qualsias...

Page 5: ...io ad innesto Articolo RR FWS ANT Antenna integrata Utilizzata con l articolo RR FWS MOT Collegamento motore Contatti per motore COM comune motore Op contatto motore APRE Cl contatto motore CHIUDE 4 G...

Page 6: ...1 TR2 1 Klux 10 Klux 20 Klux 35 Klux 55 Klux 75 Klux 99 Klux 40 Km h 25 Km h 15 Km h 5 Km h 230Vac 50Hz 7 FUNZIONAMENTO Per il comando dei motori si usano i pulsanti con ritorno automatico oppure la t...

Page 7: ...CLUSIONE E RIPRISTINO SENSORE SOLE DALLA TRASMITTENTE Per escludere o ripristinare il funzionamento del sensore sole procedere come segue esclusione sensore premere contemporaneamente i tasti di apert...

Page 8: ...essential characteristi cs of the product unchanged the manufacturer reserves himself the right to bring any change of technical con structive or commercial character without undertaking himself to up...

Page 9: ...R FWS item MOT Motor connection Motor contacts COM motor common Op OPEN motor contact Cl CLOSE motor contact 4 SENSOR MANAGEMENT If the control unit is connected with sensors for the management of wea...

Page 10: ...stroke set by the motor limit switch If the stroke must be stopped before time press the button corresponding to the reverse movement direction Transmitter operation with RR FWS accessory Button1 CLO...

Page 11: ...d constant sound At the end release the push button 11 HOW TO EXCLUDE AND RESET THE SUN SENSOR IN THE TRANSMITTER To exclude or reset the operation of the sun sensor proceed as follows sensor exclusio...

Page 12: ...Les entr es N F non utilis es doivent tre shunt es Les descriptions et les illustrations contenues dans ce manuel ne sont pas contraignantes Le fabricant se r serve le droit d apporter n importe quell...

Page 13: ...hable Article RR FWS ANT Antenne int gr e Utilis e avec la r f rence RR FWS MOT Branchement moteur Contacts pour moteur COM moteur commun Op contact moteur OUVRE Cl contact moteur FERME 4 GESTION CAPT...

Page 14: ...temps de travail normaux ouverture apr s 1 minute fermeture apr s 15 minutes temps de travail 2 minutes 7 FONCTIONNEMENT Pour commander les moteurs on utilise les interrupteurs position momentan e ou...

Page 15: ...he PL1 et appuyer encore dans 0 5 secondes et garder press pendant au moins 10 secondes durant cette p riode le buzzer met un son intermittent rapide jusqu ce que le buzzer mettra un son constant pend...

Page 16: ...ar puen teadas Las descripciones y las ilustraciones presentadas en este manual no son vinculantes Sin cambiar las ca racter sticas esenciales del producto el fabricante se reserva el derecho de aport...

Page 17: ...r de viento Conexi n sensor de viento f se al de viento g com n sensores RADIO M dulo radio enchufable Art culo RR FWS ANT Antena integrada Utilizada con el art culo RR FWS MOT Conexi n motor Contacto...

Page 18: ...elecci n de los tiempos OFF funcionamiento con tiempos de test para la primera instalaci n todas las funciones duran pocos segundos ON funcionamiento con tiempos de trabajo normales apertura al cabo d...

Page 19: ...anteni ndolo apretado durante por lo menos 10 segundos durante este periodo el zumbador emite un sonido intermitente r pido hasta que el zumbador emite un sonido constante durante 2 segundos Al final...

Page 20: ...AUTOMATISMI CAB Srl Via della Tecnica 10 z i 36010 Velo d Astico VI Italia Tel 0445 741215 Fax 0445 742094 CL8542712 02 2013 R3...

Reviews: