2
Device Control
The following control devices can be used to for the device arming/disarming:
∙
TM-key;
∙
keypad K14-LED;
∙
keypad K16-LCD;
∙
wireless keyfob CN-Keyfob;
∙
mobile application MyAlarm.
2.1
TM-Key
Figure 1: TM-reader and TM-key
The device has a built-in interface for connecting the TM-key readers. In addition, the device provides the ability
to connect the LED indicator, which is located directly in the case of some models of TM-key readers.
The LED indicator located in the TM-reader case is intended for indication of the TM-key reading, arming and
disarming, and also for indicating the device current state.
With a single TM-key it is possible to arm or disarm one partition. If one user has to be able to arm or disarm
several partitions at the same time, then the appropriate rules shall be set in the “Automatic controls” section.
2.1.1
Reading Indication
If the key reading operation has completed successfully, the device indicates this fact, regardless of whether the key
is found in the device memory or not. In other words, if the reading is successful, the device simply confirms that
a key has been brought to the reader and this key has been read.
Indication of successful reading of the TM-key: the LED “flashes” (turns on for 0.1 sec., then turns off for 0.1 sec.)
for 1 second.
2.1.2
Error Indication
The following errors are possible during a key reading:
∙
key is not found in the device memory;
∙
arming rejection.
Error indication: the LED “flashes” (turns on for 0.5 s, then turns off for 0.5 s.) for 3 seconds.