There are 4 possible settings:
SETTING
DEVIATION WITH
RESPECT TO THE
SET POINT
Low
0.25
Normal
0.50
Large
0.75
Very large
1.00
Filtration cycle
This parameter allows the user to program the start stop frequency of the two-speed pump to ensure
correct filtration of the spa water (AUTO mode).
There are 4 values to choose from:
•
every hour ;
•
every two hours ;
•
every three hours ;
•
every four hours.
Filtration time
This parameter determines the % time that the two-speed pump will run to ensure filtration. Allowed values
are between 0% and 50%, however for simplicity the filtration time is set in minutes per hour, that is
between 0 (=0%) and 30 (=50%) minutes.
Both parameters together determine the rhythm at which the filtration pump will operate.
Example 1:
The filtration cycle is set to 'every hour' and the filtration time is set to '10 minutes': If no heating demand
causes the pump to start, it will remain off for 60 minutes - 10 minutes = 50 minutes. The pump will then
run for 10 minutes and then shut down again for 50 minutes, and so on.
Example 2:
The filtration cycle is set to 'every two hours' and the filtration time is set to '10 minutes': If no heating
demand causes the pump to start, it will remain off for 120 minutes - 2 x 10 minutes = 100 minutes. The
pump will then run for 2 x 10 minutes and shut down for 100 minutes, and so on.
Nota bene :
The pump can run between 2 filtration cycles if there is a heating demand.
5.10
Factory settings
This function allows the user to return to factory settings.
•
Select Factory Settings off the main menu ;
•
Press the MENU key within the next two seconds (short authorised period)
•
The message "are you OK ?" is displayed. Select "Yes" (press the UP or DOWN arrow to toggle between
"Yes" and "No" ;
•
Press MENU to validate return to factory settings ;
45/48
2020/10 - Indice de révision : D - Code : 38050