Press MENU to change the cycle settings:
The interval setting blinks: modify this value using the UP/DOWN arrow keys, then press MENU to save
the selected value. The number of weeks lapsed now starts to blink, change this value using the UP/
DOWN arrow keys, then press MENU to save the setting.
Once the period expires, the message "maintenance required" appears on screen accompanied by the
title of the maintenance cycle.
5.8
Other Options sub-menu
This sub-menu includes the touch pad setting options.
After accessing the "Other Option" sub-menu using the MENU key; scroll through the various options using the UP
arrow key, press MENU to modify the option displayed on the screen.
Key sounds :
Activates (ON) /deactivates (OFF) the beep that sounds each time a touch pad key is pressed. Press the
arrow key to change the configuration, validate the selected configuration using the MENU key.
Screen display :
This refers to the layout of the 3 pieces of information displayed on screen. By default, the 4 large
figures indicate the spa water temperature; the set point temperature and time are displayed in small
characters on the two lines beneath the 4 large characters.
The user can change the display such that the set point temperature or time is displayed in large characters.
Another option is cycle mode, in which each of the values is displayed in large characters one after another for
10 seconds at a time.
Press the arrow key to change the current configuration, then validate the selection using the MENU key.
Screen light, colour :
Select the screen colour from the 16 available options.
Press the arrow to change the current colour, once the desired colour is displayed on screen, press
MENU to save this configuration.
Screen and spa light synchro :
Possibility to synchronise the lighting of the touch pad and the spa's underwater light. ON to synchronise,
OFF to remain independent.
Press the arrow key to change the current configuration, then when the desired setting is displayed on
screen, validate the selection using the MENU key.
5.9
Advanced Options sub-menu
The Advanced Options sub-menu provides access to settings that should only be modified after you have
familiarised yourself with the working of the spa.
After accessing the Advanced Options menu using the MENU key, scroll through the various options using
the UP arrow and press MENU to modify the option displayed on screen.
•
Temperature deviation
In addition to the water set point temperature (the spa stops heating when the set point is reached), the
user may specify the number of degrees that the spa water temperature may fall below the set point
before heating starts again.
44/48
2020/10 - Indice de révision : D - Code : 38050
SPAS