This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
8
INSTRUCTION MANUAL ECOSOFT COMMERCIAL RO SYSTEM (MO5000, MO10000)
4.2. Technical specifications
Table 2 Physical parameters
Model
MO5000
MO10000
Product code (SKU)
MO5000TP5
MO10000TP5
Rated capacity, LPH*
250
500
4040 membrane housings
1
2
Rated voltage
1 × 230 VAC, 50 Hz (free from voltage surge, dip, and any
interference)
Rated power, kW
1,0
1,0
Dimensions (Width × Depth ×
Height), cm
0,29 × 0,36 × 1,48
0,29 × 0,36 × 1,48
Approx. weight (bare / crated), kg
45/70
50/75
Ports
- feed,
- permeate,
- waste
½″ internal thread
½″ external thread
½″ external thread
½″ internal thread
½″ external thread
½″ external thread
Operating parameter specifications*
Concentrate flow, LPM
1,4
2,8
Permeate flow, LPM
4,2
8,3
Inlet water temperature, ◦C
5…30
Inlet water pressure, bar
2…4
Operating pressure, bar
8…12
*The data are indicated under the operating conditions of the system at feed water temperature of 25 °C, a salinity
of 1500 ppm, Dupont XLE-4040 membrane element, the unit efficiency is 75%, the water composition meets the
requirements in Table 1. The performance of your system may be different from these values depending on these
factors, the chemical composition of the water and other factors.
4.3. Flow rate charts
700
600
500
400
300
200
100
1000
2000
3000
4000
0,5
1
1,5
2
2,5
3
5
15
25
0
0
0
FEED WATER TDS, ppm
C
C
C
700
600
500
400
300
200
100
1000
2000
3000
4000
0,5
1
1,5
2
2,5
3
5
15
25
0
0
0
FEED WATER TDS, ppm
C
C
C
Figure 4.1
Ecosoft MO5000 flow rate chart
Figure 4.2
Ecosoft MO10000 flow rate chart
Summary of Contents for ECOSOFT MO10000