INSTRUCTION MANUAL ECOSOFT COMMERCIAL RO SYSTEM (MO5000, MO10000)
1.15 Float switch delay: delay in switching off the system at the permeate level sensor signal in
the storage tank.
1.16 Setting the display of the conductivity of the permeate as conductivity (EC) in μS/cm (if “off”)
or as TDS in ppm (mg/l). The recalculation is performed according to the formula TDS = 0.5147 EC
1.17 TDS-meter shutdown threshold: emergency shutdown threshold of the reverse osmosis unit
based on high electrical conductivity of the permeate.
1.18 Conductivity delay: the delay in shutting down the unit when the permeate conductivity
threshold is exceeded, set in menu item 1.16. If the threshold for emergency shutdown of the unit
is not set (set to zero), this menu item is not displayed.
1.19 New password for setup menu and calibration menu.
2. Calibration menu
This mode is not available in the MO5000 and MO10000 systems.
3. Maintenance menu
In this menu, the frequency of the reminder about the service maintenance of the unit is set, as
well as the blocking of the unit’s operation after the specified service interval has expired.
To enter the maintenance menu from any operating mode of the unit, press and hold the STOP
button for 8 seconds until the display prompts you to enter the settings menu. To go to the
maintenance menu, press the STOP button twice, after which the display will show the
maintenance menu prompt. To enter the maintenance menu, you need to enter the maintenance
password (by default 0000), which can be changed in p. 3.3 of the maintenance menu.
Locking: enabling / disabling the locking of the reverse osmosis unit after the maintenance period
specified in entry 3.2. If locking is disabled, then after the expiration of the maintenance period,
runtime count will proceed in negative hours (overtime). If locking is enabled, then after the service
period has expired, the unit will be locked and “Service lockout” message will be displayed, while
the operation of the unit will be blocked. To remove the lock, you need to enter the maintenance
menu and set a new maintenance period in entry 3.2.
Maintenance period: the period of operation of the reverse osmosis unit before displaying
a reminder that maintenance is required (0-32000 hours). To be set by a service technician.
Maintenance password: new password for entering the maintenance menu.