background image

EN

 T1

Typical filter capacities and bypass settings with respect to lime scale protection are

 listed on the last pages of this operation manual.

 T2

Typical filter capacities and bypass settings with respect to magnesium mineralisation are

listed on the last pages of this operation manual.

3  Usage and design

3.1  Assigned use

This BWT filter cartridge …

 

is only to be used for decarbonizing cold water fulfilling the legal requirements for drinking 

water.

 

reduces total* hardness and thus protects appliances against lime scale deposits.

 

minearalizes drinking water with magnesium.

 

protects against bacteria, cryptosporidium, giardia, protozoa and microplastics and thus pro-

vides hygienically perfect water.

 

improves flavour of bevarages by removing substances responsible for taste and odor (eg. 

chlorine).

 

filters particles* out of the water.

Any other use is deemed to be non-intended.

3.2  Design and function of the filter system

1  Pre-filtration: Removal of particles

2  Active carbon pre-filtration: Substances responsible for taste and odor (e.g. chlorine) are 

 removed, no oxidation of ion exchanger

3  Ion exchanger: Decarbonisation and mineralisation with magnesium

4  Active carbon filtration: removal of chlorine, also from bypass water

5  Ultrafiltration: retention of 99.9999% of all bacteria, cryptosporidia, giardia, protozoa, micro-

plastics, as well as natural dyes (e.g., humic acids)

4  Operating and safety instructions

Despite complying with all safety precautions, risks remain especially in case of misuse or 

 inappropriate handling. Each technical device is to be maintained and serviced regularly to 

 function  properly.

WARNING!

 

f

Any use contrary to the intended use, e.g., if the filter system is fed with water that is not of drinking water quality, results in a health 

hazard when the water is drunk: 

- Microbiological hazard due to contamination with pathogenic germs

- Hazard from too high a concentration of heavy metals or organic contamination

 

f

To protect the drinking water, maintanance and any other work on the filter system has to be carried out considering national directives 

for drinking water installations (e.g. DIN 1988, EN 1717) and applicable state and local regulations.

 

f

If the authorities or the operator of the water supply system release instructions to boil the potable water due to microbial contami-

nation it is necesary to boil the filtered water before consumption. If the drinking water quality is restored the filter system must be 

 replaced and connections cleaned.

 

f

Two type-tested non-return valves (in accordance with DIN EN 13959) are included in the filter head.

 

f

Separate the filter system from the water supply prior to maintenance work on the drinking water supply. Rinse the water line before 

reconnecting the filter system.

 

f

Disconnect the power supply of the appliance prior to installation.

3

MMWPC_NeuesDesign_pink.indd   11

05.10.2018   08:43:48

Summary of Contents for AQA drink Magnesium Mineralized Water Protect MP400

Page 1: ...eralized Water FILTER CARTRIDGES AND FILTER HEAD FOR PROTECT Filter system for optimising drinking water Installation and operating instructions AQA drink EN CARE MMWPC_NeuesDesign_pink indd 2 05 10 2...

Page 2: ...hts reserved Tous droits r serv s Todos los derechos reservados Tutti i diritti riservati Direitos reservados 0 1 2 3 7 6 5 1 1 dGH 10 ml 4 9 8 1 2 3 5 3 2 1 1 2 3 4 a E A C B D F MM TT TT MM YY MM YY...

Page 3: ...d use 3 2 Design and function of the filter system 4 Operating and safety instructions 4 1 Responsibility of the operator 4 2 Warranty and exclusion of liability 4 3 Qualified personnel 4 4 Pressure 4...

Page 4: ...17 4 Pressure loss at 30 L h 8 US gallons h bar psi 0 05 0 7 0 05 0 7 Pressure loss at 60 L h 16 US gallons h bar psi 0 10 1 5 0 15 2 2 Pressure loss at 180 L h 48 US gallons h bar psi 0 40 5 8 0 50...

Page 5: ...s natural dyes e g humic acids 4 Operating and safety instructions Despite complying with all safety precautions risks remain especially in case of misuse or inappropriate handling Each technical devi...

Page 6: ...tion against microbiological growth the filter cartridge contains a small amount of silver bacteriostatic There might be a harmless release of silver in concentrations below the recommendations of the...

Page 7: ...ressure see DIN 1988 Part 2 2 4 4 5 Operation after a break or shutdown Replacement intervals In the event of longer breaks in operation close the shut off valve in the inlet of the filter system Afte...

Page 8: ...ting is 2 The bypass can be set by pressing the button a and twisting the cap on the filter head clockwise or counter clockwise until the required bypass setting is reached and the cap snapps into pla...

Page 9: ...whilst it is in use This will remove any accumulated gases that may be trapped within the resin After a few seconds return the cartridge to the normal upright position f f The minimal flushing volume...

Page 10: ...ion is leaking Defective seal Check seal replace if necessary Air bubbles System not completely purged Repeat purging flushing procedure Section 5 6 Turbid or white water Process related formation of...

Page 11: ......

Page 12: ...CTION HYGIENICALLY SAFE WITH ULTRAFILTRATION MMWPC_NeuesDesign_pink indd 1 05 10 2018 08 43 38 BWT UK Limited BWT House The Gateway Centre Coronation Road High Wycombe Buckinghamshire HP12 3SU 04194 8...