CAUTION!

 

f

Observe all national directives for drinking water installations (e.g. DIN 1988, EN 1717) and  applicable state and local regulations, general 

sanitary requirements and technical data for the protection of drinking water.

 

f

A check (shut-off) valve upstream of the filter system must be installed.

 

f

Use only connections with gaskets or flat seals. Conical seals damage the filter head connections and will invalidate the warranty claim.

 

f

The appliance needs to be connected with hoses in accordance with DVGW W 543 or NSF 42/53.

 

f

If the product has been stored below freezing point (0 °C), leave the unpacked product at the ambient temperature of the installation 

location for a minimum of 24 hours prior to operation.

 

f

Do not install the filter system near heat sources, open fire places or naked flames.

 

f

Chemicals, solvents and vapours must not come into contact with the filter system.

 

f

The installation location must be protected against freezing and direct sunlight.

 NOTE!

 

f

For installation and operation of the filter system, the BG regulation “Rules for Safety and Health Protection When Working in Kitchens” 

of the “Food and Beverages” expert committee of BGZ (BGR111) must be observed. The filter system has been hygiene tested in accor-

dance with Section 7.4 DIN 18879-1.

 

f

The materials are selected in accordance with the requirements of DIN 18879-1 and EN 14898.

 

f

The pressure resistance of the filter system conforms to DIN 18879-1.

 

f

The filtered drinking water conforms to liquid category 2 in accordance with EN 1717.

 

f

Clean and descale the appliance, e.g. coffee machine, before firstly installing the filter system.

 

f

For immunocompromised people and infants it is recommended to boil the tap water before drinking. This also applies to filtered water.

 

f

For the protection against microbiological growth the filter cartridge contains a small amount of silver (“bacteriostatic”)*. There might 

be a harmless release of silver in concentrations below the recommendations of the World Health Organization (WHO). The term 

“bacterio static” indicates that the system limits the passage or growth of bacteria already existing in the incoming water*. It does not 

mean that the water leaving the system is safer to drink than the water entering it.

 

f

During the filtering process, the magnesium content rises slightly. If a special low-magnesium diet is to be followed, BWT recommends 

to seek medical advice.

4.1  Responsibility of the operator

 

The installation and operating instructions must be kept in the immediate vicinity of the filter 

system and must be accessible at any time.

 

The filter system may only be operated in a technically perfect state ensuring a safe 

 operation.

 

The instructions in this installation and operating manual must be followed entirely.

4.2  Warranty and exclusion of liability

BWT warrants to the original purchaser/consumer all equipment that it munufactures to be free 

from defects in material and workmanship for a period of 2 years from the date of purchase. This 

warranty is subject to exclusions and limitations

The notes and recommendations listed, as well as local drinking water and recycling  regulations, 

must be met. All information and notes in this installation and operating manual account for 

the applicable standards and regulations, state-of-the-art technology as well as our expertise 

in  water treatment. BWT does not assume any liability for damages or subsequent/secondary 

 damages arising from:

 

Failure to comply with the instructions in this installation and operating manual

 

Improper use

 

Improper or faulty installation

 

Improper commissioning, operation, maintenance

 

Mechanical damage of the filter system

 

Unauthorized modifications

 

Technical modifications

 

Use of non-certified, non-approved components

MMWPC_NeuesDesign_pink.indd   12

05.10.2018   08:43:48

Summary of Contents for AQA drink Magnesium Mineralized Water Protect MP400

Page 1: ...eralized Water FILTER CARTRIDGES AND FILTER HEAD FOR PROTECT Filter system for optimising drinking water Installation and operating instructions AQA drink EN CARE MMWPC_NeuesDesign_pink indd 2 05 10 2...

Page 2: ...hts reserved Tous droits r serv s Todos los derechos reservados Tutti i diritti riservati Direitos reservados 0 1 2 3 7 6 5 1 1 dGH 10 ml 4 9 8 1 2 3 5 3 2 1 1 2 3 4 a E A C B D F MM TT TT MM YY MM YY...

Page 3: ...d use 3 2 Design and function of the filter system 4 Operating and safety instructions 4 1 Responsibility of the operator 4 2 Warranty and exclusion of liability 4 3 Qualified personnel 4 4 Pressure 4...

Page 4: ...17 4 Pressure loss at 30 L h 8 US gallons h bar psi 0 05 0 7 0 05 0 7 Pressure loss at 60 L h 16 US gallons h bar psi 0 10 1 5 0 15 2 2 Pressure loss at 180 L h 48 US gallons h bar psi 0 40 5 8 0 50...

Page 5: ...s natural dyes e g humic acids 4 Operating and safety instructions Despite complying with all safety precautions risks remain especially in case of misuse or inappropriate handling Each technical devi...

Page 6: ...tion against microbiological growth the filter cartridge contains a small amount of silver bacteriostatic There might be a harmless release of silver in concentrations below the recommendations of the...

Page 7: ...ressure see DIN 1988 Part 2 2 4 4 5 Operation after a break or shutdown Replacement intervals In the event of longer breaks in operation close the shut off valve in the inlet of the filter system Afte...

Page 8: ...ting is 2 The bypass can be set by pressing the button a and twisting the cap on the filter head clockwise or counter clockwise until the required bypass setting is reached and the cap snapps into pla...

Page 9: ...whilst it is in use This will remove any accumulated gases that may be trapped within the resin After a few seconds return the cartridge to the normal upright position f f The minimal flushing volume...

Page 10: ...ion is leaking Defective seal Check seal replace if necessary Air bubbles System not completely purged Repeat purging flushing procedure Section 5 6 Turbid or white water Process related formation of...