8.1 AUDIO I/O
(Certain menu items are omitted in some products in the Encore range).
Within this there are two submenus – ‘inputs’ and ‘outputs’.
‘Inputs’ allows you to set the operating level of the unit when referenced to the rest of
your installation. For both analog and digital reference level, please set these to your
maximum normal operating level.
For example, if you will be feeding analog audio into the unit that may reach but never
12dBu, set the ‘analog ref level’ to +12. (For PPM users, PPM4=+4, PPM5=+8,
PPM6=+12).
Similarly, if your digital levels may meet but not exceed -10dBFS, set ‘dig ref level’ to -10.
‘Outputs’ allows you to set output levels from each physical output, and choose what
source feeds those outputs.
The sections of this submenu are:
An (analog) output source:
none
analog audio
digital audio
tuner 1 audio
tuner 2 audio
test tone (a 1kHz sine wave)
diversity
Analog output level:
-18dBu to +24dBu
Dig (digital) output source:
none
analog audio
digital audio
tuner 1 audio
tuner 2 audio
test tone
diversity
Dig output level:
-20dBFS to 0dBFS
Dig output sample rate:
48kHz
96kHz
192kHz
MPX 1 source:
none
mpx in 1*
tuner 2 mpx*
mpx generator
pilot tone
rds
MPX 1 out level:
0dBu to +12dBu**