BVME4000/6000
24
Copyright
1993,1995,1998,2001 BVM Ltd.
6.11 Protection
Fuses
The connections on the BVME4000/6000 which provide output power are protected with fuses. These
are surface-mounted fuses, and the BVME4000/6000 should be returned to factory for repair if any of
these fuses blows. For reference, the following is a list of the fuses, their functions, positions, rating
and type.
Location
(see below)
Function
Rating
Type
(LittleFuse)
F1
SCSI TERM PWR
1.5A
ALF II 42901.5
F2
ETHERNET -9V
200mA
ALF II 429.200
F3
J14 +5V
2A
ALF II 429002
F4
J14 +12V
2A
ALF II 429002
F5
IP A +12V
1A
ALF II 429001
F6
IP B +12V
1A
ALF II 429001
F7
IP B +5V
2A
ALF II 429002
F8
IP A -12V
1A
ALF II 429001
F9
IP B -12V
1A
ALF II 429001
F10
IP A +5V
2A
ALF II 429002
PERIPHERAL
CONTROLLER
82596
LANC
CHEAPERNET
CONFIG
SWITCH
LOW
PROM
HIGH
PROM
FUSES
F2
F9 F6 F1 F3 F4 F7 F10 F8 F5
Figure 26 Protection Fuse Positions