INSTRUCTION, USE AND
MAINTENANCE MANUAL
4. Mount the card (
Fig. 25 ref. 2
)
.
5. Connect ultrasound Run-out cable plug (
Fig. 25
ref. 1
) to the electronic card (
Fig. 25 ref. 2
), as
shown in
Fig. 25
(blue
ref. 4 cable,
brown
ref. 5
cable and
black
ref. 6 cable)
. Connect the ultra-
sound Run-out card (
Fig. 25 ref. 2
) to the wheel
balancer main card, using the provided cable JP18
(
Fig. 25 ref. 3
). Carry out the connection as shown
in
Fig. 25
.
Fig. 25
6. Connect the cables with clamps not to let them
hinder the ordinary operation of the machine.
7. Mount wheel balancer protection guard again.
FOR THE CONNECTIONS, REFER
TO WIRING DIAGRAMS.
9.2.11 Fitting of ultrasound Run-out with sup-
port (optional)
1. Put the 4 bolts (
Fig. 24 ref. 1
) into the gauge brack-
et (
Fig. 24 ref. 2
) and screw them to the threaded
rivets (
Fig. 24 ref. 3
) placed on the machine frame.
Lock the Run-out ultrasound arm (
Fig. 24 ref. 4
)
to the bracket (
Fig. 24 ref. 2
) using the 2 bolts
(
Fig. 24 ref. 5
) and the washers (
Fig. 24 ref. 6
).
Lock the bolts (
Fig. 24 ref. 5
) screwing the pro-
vided nuts (
Fig. 24 ref. 7
) and washers (
Fig. 24
ref. 6
).
2. Mount the ultrasounds Run-out (
Fig. 24 ref. 8
) as
illustrated in
Fig. 24
.
Fig. 24
3. Demount wheel balancer bridge.
1301-M001-02