13.10 Recalculation function
After making a spin, the wheel automatically stops,
indicating the weight/s to be fitted and its/their position.
In case the operator does not want the type of wheel
balance proposed by the machine (program type,
weights size, etc ...), proceed with the re-calculation
of the wheel balancing without rerunning the spin of
the wheel.
To do this, proceed as described below:
- press the button
to return to the measures
detection/program selection page;
- select a new balancing program as indicated in Par.
13.2.2;
- take with the gauge arm the measures required by
the selected program;
- press button
to perform the re-calculation.
The monitor will display the weights and the posi-
tions in which they will be applied.
If also in this case the operator should decide to fur-
ther modify the balancing program, it is sufficient to
proceed as described above without having to spin
the wheel.
When the result of the recalculation does not satisfy
the operator, it is recommended to do a spin of the
wheel to confirm the findings from the operation of
recalculation itself.
After the launch of the wheel, the machine, in addi-
tion to displaying the unbalance value, draw up au-
tomatically all the programs measurement fields that
are consistent with those measures that were taken
previously and at the same time erases all measures
which are not consistent.
13.11 Wheel balancing in Motorcycle mode
(with distance caliper extension Kit)
By enabling “motorcycle wheel balancing” function, the
wheel balancers can also balance motorcycle wheels.
Before detecting the wheel sizes (see Par. 13.2.2), se-
lect motorcycle wheel balancing mode proceeding as
described below:
press the button
, then the button
and,
finally, press the button
to go to measurement
acquisition program selection screen page.
Use arrows
and/or
to select the mode
desired.
At the end press push button
.
The machine will be configured as follows to perform
the measurement in the desired mode and on the
screen will appear an indication showing the measures
that will be acquired.
The "motorcycle" mode automatically recalculates
the wheel distance measurement, increasing it by the
length of the extension supplied with distance caliper
extension kit (kit available on demand).
THE EXTENSION MUST BE FIT-
TED ONLY WHEN BALANCING IS
PERFORMED IN "MOTORCYCLE"
MODE.
TO MOUNT THE EXTENSION AND
THE COMPONENTS OF CALIPER
EXTENSION KIT, PLEASE REFER
TO THE SPECIFIC INSTRUCTIONS
INCLUDED IN THE KIT.
Balancing procedures are identical for both modes
(car/motorcycle).
By selecting motorcycle mode, besides DYNAMIC bal-
ancing (see Par. 13.7.4) STATIC balancing and/or ALU-
S (Par. 13.7.1 and/or 13.7.5) can also be performed.
LIBRAK350 - LIBRAK350PRO