Page 24 of 61
INSTRUCTION, USE AND
MAINTENANCE MANUAL
EN
- Press the button
to display the following pro-
grams selection screen page:
Use the arrows
and/or
to select the
wished mode (yellow). In this mode you can select
the 11 standard programs (listed above) and special
programs (PAX360, PAX420, PAX460, PAX700).
AFTER YOU HAVE SELECTED THE
DESIRED PROGRAM, USE THE
DISTANCE-DIAMETER CALIPER
AND/OR THE EXTERNAL DATA
GAUGE (IF ANY) TO DETECT THE
MEASURES REQUIRED BY THE
PROGRAM.
WHENEVER THE DISTANCE-DI-
AMETER CALIPER AND/OR THE
EXTERNAL DATA GAUGE (SEE
FIG. 23(IF ANY) IS KEPT IN PO-
SITION FOR A FEW SECONDS
AGAINST THE RIM (UNTIL THE
MACHINE MAKES AN APPRO-
PRIATE SOUND NOTIFICATION),
THE POSITION IS STORED AND
THE VALUES MEASURED IN THE
PRE-ARRANGED FIELDS IN THE
SELECTED WHEEL BALANCING
PROGRAM ARE LOADED.
- After entering all the required measures, you can spin
the wheel by pressing the button
and closing
the protective guard.
13.3 Indicative display of points where to
detect measures/to fit weight
IT IS VERY IMPORTANT TO RE-
MEMBER THE POINTS SELECTED
FOR MEASUREMENT INSIDE THE
RIM SINCE DURING THE WEIGHTS
FITTING WITH FIXED LASER YOU
WILL NOT HAVE ANY OTHER
REFERENCE EXCEPT FOR THE
CROSS LINE ON THE RIM, GEN-
ERATED BY THE LASER ITSELF.
THE POSITIONING IN DEPTH WILL
BE AT THE DISCRETION OF THE
OPERATOR.
Depending on the type of program selected,the machine
shows on the monitor the guideline points where to
take measures and, consequently, where you must
apply weights (
Fig. 29 ref. 4-5
).
Fig. 29
2
5
1
5
3
4
6
KEY
1 – 1
st
weight fitting point distance
2 – Rim diameter
3 – Balancing mode
4 – Point at which to take the measure/adhesive
weight fitting
5 – Point at which to take the measure/clip weight
fitting
6 – Rim width
THE MORE THE POINTS CHOSEN
FOR THE PROBING ARE DISTANT
FROM EACH OTHER THE MORE
THE BALANCING WILL BE EFFEC-
TIVE.
1296-M024-01
LIBRAK350 - LIBRAK350PRO