Checking the Colour of the Oil

Note

: The oil should be light, either transparent, a little foamy or a little

tarnished. A milky discolouration that does not vanish after sedation of
the oil indicates contamination with foreign material. Oil that is either
contaminated with foreign material or burnt must be changed
(

Ú

page 10: Oil Change).

In case the oil appears to be contaminated with water or other conden-
sates despite proper use of the gas ballast:

Replace the filter.

Oil Life

The oil life depends very much on the operating conditions. A clean
and dry air stream and operating temperatures below 100 °C are ideal.
Under these conditions the oil shall be changed every 500 to 2000 op-
erating hours or after half a year.

Under very unfavourable operating conditions the oil life can be less
than 500 operating hours. Extremely short life times indicate malfunc-
tions (

Ú

page 13: Troubleshooting) or unsuitable operating conditions,

though.

Chosing a synthetic oil instead of a mineral oil can extend the oil life.
To select the oil best suited oil for your process please contact your
Busch representative.

If there is no experience available with regard to the oil life under the
prevailing operation conditions, it is recommended to have an oil ana-
lysis carried out every 500 operating hours and establish the change in-
terval accordingly.

Oil Change

DANGER

_age32

In case the vacuum pump conveyed gas that was contaminated
with harmful foreign material the oil will be contaminated with
harmful material.

Danger to health during the changing of contaminated oil.

Danger to the environment.

Personal protective equipment must be worn during the changing
of contaminated oil.

Contaminated oil is special waste and must be disposed of sepa-
rately in compliance with applicable regulations.

Draining Used Oil

Note

: After switching off the vacuum pump at normal operating tem-

perature wait no more than 20 minutes before the oil is drained (the oil
shall still be warm when being drained).

Make sure that the vacuum pump is shut down and locked against
inadvertent start up

Make sure that the vacuum pump is vented to atmospheric pres-
sure

Put a drain tray underneath the drain port (i)

Remove the drain plug (i) and drain the oil

When the oil stream dwindles:

Reinsert the drain plug (i)

Switch the vacuum pump on for a few seconds

Make sure that the vacuum pump is shut down and locked against
inadvertent start up

Remove the drain plug (i) again and drain the remaining oil

Make sure that the seal ring is inserted into the drain plug (i) and
undamaged, replace if necessary

Firmly reinsert the drain plug (i) together with the seal ring

Dispose of the used oil in compliance with applicable regulations

Flushing the Vacuum Pump

WARNING

_ad

Degraded oil can choke pipes and coolers.

Risk of damage to the vacuum pump due to insufficient lubrica-
tion.

Risk of explosion due to overheating.

If there is a suspicion that deposits have gathered inside the
vacuum pump the vacuum pump shall be flushed.

Make sure that all the used oil is drained

Create 0.4 litres flushing agent from 50 percent oil and 50 percent
paraffin or diesel fuel/fuel oil

Make sure that the drain plug (i) is firmly inserted

Remove the filling plug (d)

Fill in the flushing agent

Firmly reinsert the filling plug (d)

Close the suction line

Run the vacuum pump for at least half an hour

Drain the flushing agent and dispose of it in compliance with appli-
cable regulations

Note

: Due to the use of paraffin and even more in case of using diesel

fuel/fuel oil, an unpleasant odour can occur after recommissioning. If
this is a problem, diesel fuel/fuel oil should be avoided and the vacuum
pump be run at idle in a suitable place until the unpleasant odour
vanishes.

Filling in Fresh Oil

Keep 0.4 litres oil acc. to the table Oil (

Ú

page 18) ready

Note

: The amount given in these operating instructions is a guide. The

sight glass (j) indicates the actual amount to be filled in.

Make sure that the drain plug (i) is firmly inserted

CAUTION

_a

Filling oil through the suction connection (h) will result in breakage
of the vanes and destruction of the vacuum pump.

Oil may be filled through the filling port (d) only.

Remove the filling plug (d)

Fill in approx. 0.4 litres of oil

Make sure that the level is at about 75 percent of the sight glass (j)

Make sure that the seal ring is inserted into the filling plug (d) and
undamaged, replace if necessary

Firmly reinsert the filling plug (d) together with the seal ring

Exhaust Filter

Checks during Operation

Busch recommends the use of a filter pressure gauge (available as an 
accessory). Without filter pressure gauge the filter resistance shall be
assessed on the basis of the drive motor current drawn.
  

Version with exhaust filter pressure gauge:

Remove the suction line from the suction connection (h) (unre-
stricted suction!)

Make sure that the vacuum pump is running

Check that the reading on the filter pressure gauge is in the
green field

Reconnect the suction line to the suction connection (h)

                                                                                          10

Summary of Contents for R 5 RA/RC 0010 C

Page 1: ...Installation and Operating Instructions Rotary Vane Vacuum Pumps R 5 RA RC 0010 0016 C Busch LLC 516 Viking Drive Va Beach VA 23452 Phone 757 463 7800 Fax 757 463 7407 P N 0872 918 377 0909 ...

Page 2: ......

Page 3: ...shooting 13 Oil 18 EC Declaration of Conformity 19 Service Centers 20 Busch All over the World in Industry 21 2 Preface Congratulations on your purchase of the Busch vacuum pump With watchful observation of the field s requirements innovation and steady development Busch delivers modern vacuum and pressure solutions worldwide These operating instructions contain information for product description...

Page 4: ...id reverse rotation after switching off the vacuum pump is equipped with a non return valve Note This valve shall not be used as a non return valve or shut off valve to the vacuum system and is no reliable means to prevent suction of oil into the vacuum system while the vacuum pump is shut down In case the vacuum pump is equipped with a gas ballast optional Through the gas ballast a small amount o...

Page 5: ... the vacuum pump these installation and operating instructions shall be read and understood If anything remains to be clarified please contact your Busch representative Safety Notes The vacuum pump has been designed and manufactured according to state of the art methods Nevertheless residual risks may remain These operating instructions highlight potential hazards where appro priate Safety notes a...

Page 6: ...ack the surfaces of plastics and elastomers Seek advice from your local packaging dealer Busch uses CORTEC VCI 126 R film for the overseas packaging of large equipment Wrap the vacuum pump in VCI film Store the vacuum pump if possible in original packing indoors dry dust free and vibration free For commissioning after conservation Make sure that all remains of adhesive tape are removed from the po...

Page 7: ...condensates can be drained from the suction line Make sure that the suction line does not contain foreign objects e g welding scales CAUTION_a The discharged gas contains small quantities of vacuum oil Staying in vacuum oil contaminated air bears a risk of damage to health If air is discharged into rooms where persons stay sufficient ventila tion must be provided for Electrical Connection Controls...

Page 8: ... to be filled in CAUTION_a Filling oil through the suction connection h will result in breakage of the vanes and destruction of the vacuum pump Oil may be filled through the filling port d only CAUTION_a During operation the oil separator is filled with hot pressurised oil mist Risk of injury from hot oil mist with open filling port Risk of injury if a loosely inserted filling plug d is ejected Re...

Page 9: ...quired contact or heat protection gloves shall be worn CAUTION_a The gas conveyed by the vacuum pump contains remainders of oil Aspiration of process gas over extended periods can be harmful The room into which the process gas is discharged must be suffi ciently vented Make sure that all provided covers guards hoods etc remain mounted Make sure that protective devices will not be disabled Make sur...

Page 10: ...lle and the cooling fins Every Year Make sure that the vacuum pump is shut down and locked against inadvertent start up Replace the exhaust filter Ú page 10 Exhaust Filter In case an inlet air filter is installed Replace the inlet air filter Check the inlet screen clean if necessary Version with gas ballast with paper filter Replace the filter Every 500 2000 Operating Hours Ú page 10 Oil Life Chan...

Page 11: ...dvertent start up Remove the drain plug i again and drain the remaining oil Make sure that the seal ring is inserted into the drain plug i and undamaged replace if necessary Firmly reinsert the drain plug i together with the seal ring Dispose of the used oil in compliance with applicable regulations Flushing the Vacuum Pump WARNING_ad Degraded oil can choke pipes and coolers Risk of damage to the ...

Page 12: ...r retaining spring but do not remove it at this time Press the exhaust filter retaining spring out of the indent and rotate it Remove the exhaust filter retaining spring from the oil sepa rator e Pull the exhaust filter out of the oil separator e Inserting the Exhaust Filter CAUTION_a The non OEM spares market offers exhaust filters that are geomet rically compatible with Busch vacuum pumps but do...

Page 13: ...motor If deposits could have gathered in the vacuum pump Flush the vacuum pump Ú page 9 Maintenance Observe the chapter Installation and Commissioning Ú page 5 Dismantling and Disposal DANGER_age32 In case the vacuum pump conveyed gas that was contaminated with harmful foreign material the oil and the exhaust filter s will be contaminated with harmful material Harmful material can reside in pores ...

Page 14: ...oil the most common cause Change the oil Ú page 9 Maintenance No or not enough oil in the reservoir Top up oil Ú page 9 Maintenance The exhaust filter is partially clogged Replace the exhaust filter Ú page 9 Maintenance The screen in the suction connection h is partially clogged Clean the screen If cleaning is required too frequently install a filter upstream In case a filter is installed on the s...

Page 15: ...or is overloaded Supply the drive motor with the correct volt age The drive motor starter overload protection is too small or trip level is too low Compare the trip level of the drive motor starter overload protection with the data on the nameplate correct if necessary In case of high ambient temperature set the trip level of the drive motor starter overload protection 5 percent above the nominal ...

Page 16: ...ommission ing Loose connection s in the drive motor termi nal box Version with three phase motor Not all drive motor coils are properly con nected The drive motor operates on two phases only Check the proper connection of the wires against the connection diagram particularly on motors with six coils Tighten or replace loose connections Version with three phase motor The vacuum pump runs in the wro...

Page 17: ...ging of filters or screens Partial clogging in the suction discharge or pressure line Remove the clogging Long suction discharge or pressure line with too small diameter Use larger diameter The vacuum pump fumes or expels oil drop lets through the gas discharge The oil level drops The exhaust filter is not properly seated Check the proper position of the exhaust fil ter if necessary insert properl...

Page 18: ...oil life is too short use oil with better heat resistance Ú page 18 Oil or ret rofit cooling The oil is watery and coloured white The vacuum pump aspirated water or signifi cant amounts of humidity Version with gas ballast The filter of the gas ballast is clogged Flush the vacuum pump Replace the exhaust filter Fill in new oil Ú page 9 Maintenance Modify the operational mode Ú page 8 Op erating No...

Page 19: ...Oil l x o r p p a y t i t n a u q g n i l l i F 18 Recommended oil type Busch R 580 0 4 l x o r p p a y t i t n a u q g n i l l i F Alternative oil type 0 4 VM 068 VSL 068 ...

Page 20: ...ithin Certain Voltage Limits so called Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC have been designed and manufactured to the following specifications Standard Title of the Standard Harmonised Standards EN ISO 12100 1 EN ISO 12100 2 Safety of machinery Basic concepts general principles of design Part 1 and 2 EN 294 Safety of machinery Safety distance to prevent danger zones be...

Page 21: ...t 420 E Street Suite 4 South Plainfield NJ 07080 Minillas Industrial Park Phone 908 561 3233 Bayamon PR 00959 1901 Fax 908 561 3909 Phone 787 798 5045 service nj buschusa com Fax 787 798 5033 service pr buschusa com Texas Virginia 1901 South Starpoint Drive 516 Viking Drive Houston TX 77032 Virginia Beach VA 23452 Phone 281 214 8400 Phone 757 463 7800 Fax 281 214 8410 Fax 757 463 7407 service tx b...

Page 22: ......

Page 23: ......

Page 24: ...owth Junction Business Centre Kilbarrack Dublin 5 Tel 00353 1 832 1466 Fax 00353 1 832 1470 Italy Busch Italia S r l Via Ettore Majorana 16 20054 Nova Milanese Tel 0362 370 91 Fax 0362 370 999 Japan Nippon Busch K K 1 23 33 Megumigaoka Hiratsuka City Kanagawa Japan 259 1220 Tel 0463 50 4000 Fax 0463 50 4004 Korea Busch Korea Ltd 392 1 Yangji Ri Yangji Myun Yongin si Kyunggi Do Tel 031 321 8114 Fax...

Reviews: