5 | Installation
8 / 24
Instruction Manual R5 KD 0012-0020 A_EN_en
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that the oil sight glass (OSG) remains easily visible.
• Make sure that enough space remains for maintenance work.
• Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction is acceptable.
• Check the oil level, fill up if necessary, see
.
• Make sure that all provided covers, guards, hoods, etc. are mounted.
• Fix the pump unit with M6-screws to the housing of the table top-packing machine.
• You can use the same fixing screws even if you use the rubber feet for absorbing vibrations.
These conditions are recommended installation conditions made by the manufacturer
Busch. If you have questions, contact Busch.
5.2 Connecting Lines / Pipes
• Remove all protective covers before installation.
• Make sure that the connection lines cause no stress on the machine‘s connection; if
necessary use flexible joints.
• Make sure that the line size of the connection lines over the entire length is at least as
large as the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a
loss of efficiency. Seek advice from your Busch representative.
5.2.1 Suction Connection
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
• Install a suitable filter (5 micron or less) upstream from the machine.
Connection size(s):
– G1/2
NOTICE
Using the non-return valve as shut off valve.
Risk of oil mist flow back into the vacuum system.
• It is highly recommended not to use the non-return valve as a shut off system.
5.2.2 Discharge Connection
CAUTION
The discharge gas contains small quantities of oil.
Risk to health!
If air is discharged into rooms where persons are present:
• Make sure that sufficient ventilation is provided.
Connection size(s):
– Without connection. The discharged gas is released to the ambient of the machine.
Summary of Contents for KD 0012 A