Installation | 5
Instruction Manual R5 KD 0012-0020 A_EN_en
11 / 24
Motor Variants
Motor voltage Motor frequency
Motor speed
Capacitor
capacitance
Capacitor volt-
age
220 – 240 V
50 / 60 Hz
3000 /
3600 min
-1
20
µ
F
400 V
110 /
110 – 120 V
50 / 60 Hz
3000 /
3600 min
-1
40
µ
F
250 V
100 V
50 / 60 Hz
3000 /
3600 min
-1
40
µ
F
250 V
5.4.2 Capacitor Installation
The machine needs a suitable capacitor (CAP) to operate, see
Depending on the order, the scope of delivery contains one of the following delivery options.
1. Delivery option:
The capacitor (CAP) is delivered loosely with 2 cable ties
• Install the capacitor (CAP) on the capacitor’s support (CS) of the motor and connect
the capacitor connection (CC).
• For thermal reasons, the capacitor (CAP) can be mounted at a different location.
Maximum distance of 230 mm (cable length) from the capacitor connection (CC).
2. Delivery option:
The capacitor (CAP) is installed on the capacitor’s support (CS)
• connect the capacitor connection (CC).
• For thermal reasons, the capacitor (CAP) can be mounted at a different location.
Maximum distance of 230 mm (cable length) from the capacitor connection (CC).
3. Delivery option:
No capacitor (CAP)
• Depending on the motor, install a suitable capacitor (CAP), see
.
• Install the capacitor (CAP) on the capacitor’s support (CS) of the motor and connect
the capacitor connection (CC). (see above picture)
• For thermal reasons, the capacitor (CAP) can be mounted at a different location.
Maximum distance of 230 mm (cable length) from the capacitor connection (CC).
Summary of Contents for KD 0012 A