Installation | 5
0870567093_NC0630C_ACV_A0002_IM_en
11 / 36
5.2.2 Discharge Connection
Connection size:
At the machine discharge connection:
– DN100 ISO-K, DIN 28404
At the silencer (SI) discharge connection (two optional versions available):
– DN80 PN16 + ANSI/ASME B16.5-3” class 150 lbs
– R3
• Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line or use it as a pressurised air source.
• Make sure that the counter pressure at the discharge connection (OUT) does not ex-
ceed the admissible pressure, see
Technical Data [
►
34]
.
5.2.3 Barrier Gas System Connection (Optional)
Without nitrogen panel
PRV
FR
BGC
MAN
FME
BGC
Barrier gas connection
FME
Flow meter
FR
Flow regulator
MAN
Manometer
PRV
Pressure regulating valve
With nitrogen panel
PRV
MV
BGC
MAN
FME, FS
NIP
BGC
Barrier gas connection
FME
Flow meter
All manuals and user guides at all-guides.com
all-guides.com