Installation | 5
0870567093_NC0630C_ACV_A0002_IM_en
13 / 36
Gas type
Dry nitrogen
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
2.5
Filtration
µm
5
Recommended flow rate
SLM*
30
* standard litre per minute
5.2.5 Purge Gas System Connection (Optional)
PRV
MV
PGC
MAN
FME, FR
INF
NIP
PGC
Purge gas connection
FME
Flow meter
FR
Flow regulator
INF
Inlet flange
MAN
Manometer
MV
Solenoid valve
NIP
Nitrogen panel
PRV
Pressure regulating valve
• Connect the purge gas connection to the gas supply.
Connection size:
– G1/4, ISO 228-1
• Electrically connect the solenoid valve (MV), see
Wiring Diagram Solenoid Valve
[
►
19]
.
• Make sure that the gas complies with the following requirements:
Gas type
Dry nitrogen
Gas temperature
°C
0 ... 60
Maximum gas pressure
bar
13
Recommended pressure setting at the
pressure regulating valve (PRV)
bar
2.5
Filtration
µm
5
Recommended flow rate
SLM*
≥
100
* standard litre per minute