Installation | 5
0870567093_NC0630C_ACV_A0002_IM_en
17 / 36
• Electrically connect the two level switches (LS), see
Wiring Diagram Level Switch
[
►
21]
.
• Fill the flushing liquid vessel (FLV) with a process compatible flushing liquid.
5.6 Fitting the Coupling
E
Coupling hub (machine side)
Coupling hub (motor side)
Coupling spider
Radial screw
Max. admissible
torque: 10 Nm
Machine type
Coupling size
Value “E” (mm)
NC 0600 C
ROTEX
®
42
26
NC 0630 C
NC 0630 C
ROTEX
®
48
28
In case of a machine delivery without motor:
• Fit the second coupling hub on the motor shaft (separately delivered).
• Axially adjust the hub in such a way until value "E" is reached.
• When the coupling adjustment is done, lock the coupling hub by tightening the
radial screw.
• Mount the motor on the machine by including the coupling spider.
For further coupling information, go to
www.ktr.com
and download the instruction
manual of the ROTEX
®
coupling.
5.7 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• Provide overload protection according to EN 60204-1 for the motor.
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Connect the protective earth conductor.
• Electrically connect the motor.
All manuals and user guides at all-guides.com