Safety
Intended use
DEFINITION
: For the purpose of correct understanding, the “handling”
of the vacuum pump implies the transport, storage, installation,
commissioning, the influence on operating conditions, maintenance,
troubleshooting and overhaul of the vacuum pump.
The vacuum pump is intended for industrial use. It should only be
handled by qualified staff.
The different applications for use and operational limits of the vacuum
pump as laid out in the “Product Description” and the “Installation
Prerequisites” of the vacuum pump must be observed both by the
manufacturer of the machinery into which the vacuum pump is to be
incorporated and by the end user.
The need for personal safety regulations depends mainly on the
application the pump will be used in. The end user must provide the
operators with all necessary means and tools and must inform his
personnel about any dangers emanating from the processed products.
The operator of the vacuum pump must observe the safety regulations
and must train and instruct his personnel accordingly.
The maintenance instructions must be observed and respected.
Is is vital that these installation and maintenance instructions are read
and understood before the vacuum pump is used. If you have any
doubts, please contact your local Busch representative.
Safety information
The vacuum pump has been designed and manufactured in accordance
with the latest technical and safety standards. However, residual risks
may remain.
A lot of safety information is mentioned in these Installation and
Operating Instructions as well as on the pump. The safety instructions
must be observed. The safety information can quickly be detected
through key words like DANGER, WARNING and CAUTION and is
defined as follows:
DANGER
Disregard of this safety note will always lead to accidents with
potentially fatal injuries and serious damages.
WARNING
Disregard of this safety note may lead to accidents with potentially
fatal injuries and serious damages.
CAUTION
Disregard of this safety note will always lead to accidents with minor
injuries and damages to property.
Safety stickers
Sound emissions
Refer to the table “Technical data” for permissible sound levels in free
field conditions according to EN ISO 2151.
CAUTION
The vacuum pump emits noise of high intensity.
Risk of damage to the hearing.
Persons staying in the vicinity of a non noise insulated vacuum
pump over extended periods shall wear ear protection.
Stopping procedure for maintenance
l
Inertise the vacuum pump (see page 13)
l
Stop the vacuum pump
l
Switch off power supply (the vacuum pump must be fully
disconnected from any power supply)
l
Put up label or warning board “Maintenance in progress” on or
next to the pump
Start-up procedure after maintenance
l
Remove label or warning board “Maintenance in progress”
l
Check cooling liquid and oil levels according to the chapters
“Checking the oil level” and “Checking the cooling liquid level”
l
Switch on power supply (the vacuum pump must be connected to
the power supply)
l
Check that the “Installation prerequisites” are observed
l
Start the vacuum pump
Transport
The COBRA NC vacuum pumps are tested and checked in our factory
before careful packing. Check the packaging for transport damage
when the goods arrive. The pump can withstand temperatures
between -20°C and +55°C during transport.
Transportation of packaged pump
Packed on a pallet, the vacuum pump can be transported with a
forklift.
Transport in unpacked state
The vacuum pump is bolted to a pallet or a base plate:
u
Remove the bolts between the vacuum pump and the pallet or
base plate
Safety
Page 5
Kühlmitteleinfüllung: 40% Frostschutz gemäss Betriebsanleitung / 60% Wasser
Cooling Medium Filling: 40% Antifreeze according Operating Manual / 60% Water
Liquide de refroidissement: 40% Antigel selon manuel d’installation / 60% Eau
Achtung heiss! / Warning hot! / Attention chaud!
Danger! Do not remove the plug when unit is hot!
Danger! Ne pas ouvrir le bouchon pompe chaude!
Gefahr! Stopfen nicht bei heisser Pumpe öffnen!
Warnung !
Der Versand der Pumpe erfolgt ohne Kühlflü-
sigkeit- und/ oder Ölfüllung !
Bei der Inbetriebnahme unbedingt die Angaben
in der Betriebsanleitung beachten !
Warning !
Pumps are shipped without cooling liquid and/
or oil !
Please refer to the instructions in the manual
before starting the pump !
Attention !
Les pompes sont expédiées sans liquide de
refroidissement et/ ou sans huile !
Veuillez vous référer aux instructions du
manuel lors de la mise en service !
Achtung! Vakuumpumpe darf nur bei Stillstand
und außerhalb explosionsfähiger Atmosphäre
geöffnet werden!
Caution! Open the pump only after complete shut
down and outside of a potentially explosive
atmosphere!
Summary of Contents for 7180551
Page 24: ......
Page 26: ...Temperature sensor TS Temperature sensor TS Page 26...
Page 27: ...Temperature sensor TS Page 27...
Page 28: ...Temperature sensor TS Page 28...
Page 29: ...Temperature sensor TS Page 29...
Page 34: ...Note...
Page 35: ...Note...