© 2019 Burnside Telecom Ltd.
Page 12 of 25
Rev 2.1
16
*816*n#
Select DC feed current of FXS port:
To increase the current for compatibility with older telephone equipment.
0 = 20 milliamps (mA)
1 = 25 mA (default)
2 = 30 mA
17
*817*n#
Call progress announcement mode:
Instead of tones, voice announcements may be played to suit the condition of the
terminal. For example,
“We are unable to connect your call, please try again later”
0 = No announcements, only progress tones (default).
1 = Normal dial tone, then progress announcements.
*855# Listen to
“being connected” announcement.
18
*818*n#
Call progress announcement and PA output level:
The output level of announcements may be adjusted.
0 = -9dB
1 = -6dB
2 = -3dB
3 = Normal level (default).
4 = +3dB
5 = +6dB
6 = +6dB
19
*819*n#
Automatic sending of SMS status:
The status of the terminal may be sent automatically either when an error event
occurs or regularly at specified intervals. The time is set wi
th the “STIME” command
and the destination number for the SMS is set wit
h “PNUM11”.
0 = No report (default).
1 = Report status type 1 when an event occurs.
2 = Report status type 1 daily at time specified and when event occurs.
3 = Report status type 2 when an event occurs.
4 = Report status type 2 daily at time specified and when event occurs.
5 = Report status type 3 (M2M) when an event occurs.
6 = Report status type 3 (M2M) daily at time specified and when event occurs.
20
*820*n#
Event conditions to report:
When reporting on error condition is enabled with CFG20=1-4, events that trigger
a report may be controlled by setting bits with this command.
Bit number
Function
Default setting
Decimal
0
Battery condition
1
1
1
Temperature
1
2
2
Hook howl state
1
4
3
Power break
1
8
4
On/off state change
1
16
5
Low PSTN voltage
1
32
6
Extended PSTN tests
0
64
The default value with 6 conditions enabled is 63.