Appliance materials of construction, products of combustion and the fuel contain alumina, silica, heavy metals, 

carbon monoxide, nitrogen oxides, aldehydes and/or other toxic or harmful substances which can cause death or 

serious injury and which are known to the state of California to cause cancer, birth defects and other reproductive 

harm. Always use proper safety clothing, respirators and equipment when servicing or working nearby the appliance.

This boiler contains very hot water under high pressure. Do not unscrew any pipe fittings nor attempt to disconnect any 

components of this boiler without positively assuring the water is cool and has no pressure. Always wear protective 

clothing and equipment when installing, starting up or servicing this boiler to prevent scald injuries. Do not rely on 

the pressure and temperature gauges to determine the temperature and pressure of the boiler. This boiler contains 

components which become very hot when the boiler is operating. Do not touch any components unless they are cool.

This appliance must be properly vented and connected to an approved vent system in good condition. Do not operate 

boiler with the absence of an approved vent system.

This boiler needs fresh air for safe operation and must be installed so there are provisions for adequate combustion 

and ventilation air.

The interior of the venting and air intake systems must be inspected and cleaned before the start of the heating season 

and should be inspected periodically throughout the heating season for any obstructions. Clean and unobstructed 

venting and air intake systems are necessary to allow noxious fumes that could cause injury or loss of life to vent 

safely and will contribute toward maintaining the boiler’s efficiency.

This boiler is supplied with controls which may cause the boiler to shut down and not re-start without service. If damage 

due to frozen pipes is a possibility, the heating system should not be left unattended in cold weather; or appropriate 

safeguards and alarms should be installed on the heating system to prevent damage if the boiler is inoperative.

This boiler is designed to burn No. 2 fuel oil, natural and/or LP gas only. Do not use gasoline, crankcase drainings, 

or any oil containing gasoline. Never burn garbage or paper in this boiler. Do not convert to any solid fuel (i.e. wood, 

coal). All flammable debris, rags, paper, wood scraps, etc., should be kept clear of the boiler at all times. Keep the 

boiler area clean and free of fire hazards.

Always keep the oil supply valve shut off if the burner is shut down for an extended period of time.

Probe and float type low water cutoff devices require annual inspection and maintenance. Refer to instructions in 

Section IV for inspection and cleaning instructions.

Les matériaux d’assemblage de l’appareil, les produits de combustion et le combustible contiennent de l’alumine, de 

la silice, des métaux lourds, du monoxyde de carbone, des oxydes d’azote, des aldéhydes ou d’autres substances 

toxiques ou dangereuses pouvant causer la mort ou des blessures graves, et qui ont été reconnues par l’État de 

la Californie comme causes de cancer, d’anomalies congénitales et d’autres problèmes de l’appareil reproducteur. 

Toujours utiliser des vêtements, des appareils respiratoires et de l’équipement de sécurité appropriés lors du travail 

ou de l’entretien près de l’unité.
Cette chaudière contient de l’eau très chaude sous haute pression. Ne pas dévisser les raccords de tuyau ni tenter 

de retirer tout composant sans s’assurer hors de tout doute que l’eau est froide et la pression inexistante. Toujours 

porter des vêtements et de l’équipement de protection pour installer, démarrer ou réparer cet appareil afin d’éviter les 

échaudures. Ne pas se fier aux jauges de pression et de température de la chaudière pour déterminer ces variables. 

Certains composants de cet appareil deviennent très chauds lors du fonctionnement. Ne pas toucher les composants 

qui ne sont pas froids.

Cet appareil doit être installé dans un endroit bien aéré et raccordé à un système de ventilation certifié en bonne 

condition. Ne pas faire fonctionner sans ventilation.
Pour fonctionner de façon sécuritaire, cette chaudière nécessite de l’air frais et doit être installée de façon à ce que 

les conditions de combustion et de ventilation soient adéquates.
L’intérieur des prises d’air et des conduites d’évacuation doit être inspecté et nettoyé avant la saison froide, puis 

inspecté régulièrement en cours de saison pour prévenir les engorgements. La propreté et l’absence d’obstruction 

des prises d’air et des conduites d’évacuation sont nécessaires à l’évacuation sécuritaire des émanations toxiques 

pouvant causer des blessures ou la mort, et contribuent à maintenir l’efficacité de la chaudière.

Cette chaudière est munie de commandes pouvant provoquer un arrêt qui l’empêchera de redémarrer si elle n’est pas 

réparée. Si le gel des tuyaux peut causer un bris, ne pas laisser le système de chauffage sans surveillance en temps 

froid, ou encore, installer une alarme ou une protection appropriée au système afin de prévenir des dommages si la 

chaudière est inefficace.
Cette chaudière est conçue pour n’utiliser que du mazout lourd no 2, du gaz naturel ou du gaz de pétrole liquéfié. Ne 

pas utiliser d’essence, de vidanges de carter de moteur ou toute huile contenant de l’essence. Ne pas faire brûler 

de déchets ni de papier dans la chaudière. Ne pas utiliser de combustible solide (bois, charbon). Tenir tout débris, 

tissu, papier, résidu de bois ou autre loin de la chaudière en tout temps. Garder l’espace autour de l’appareil propre 

et sans risque d’incendie.
Toujours fermer la vanne d’alimentation de mazout si le brûleur est arrêté pour une durée prolongée.

Les interrupteurs à bas niveau d’eau de type sonde ou de type flotteur doivent être inspectés et entretenus annuellement. 

Voir les directives de la section IV concernant l’inspection et le nettoyage.

Summary of Contents for 4FHL-107A

Page 1: ...hnician BEFORE installing read all instructions in this manual and all other information shipped with the boiler Post all instructions and manuals near the boiler for reference by service personnel Pe...

Page 2: ...es having jurisdiction should be consulted before installations are made C All wiring on boilers installed in Canada shall be made in accordance with the Canadian Electrical Code and or Local Regulati...

Page 3: ...ne Burner boiler systems produce steam or hot water in a pressurized vessel by mixing extremely flammable gaseous liquid or solid fuels with air to produce combustion and very hot products of combusti...

Page 4: ...e s ret sont absents ou install s l aide de cavaliers Ne pas faire fonctionner si une commande un interrupteur un composant ou un dispositif est entr en contact avec de l eau Improper installation adj...

Page 5: ...e combustible contiennent de l alumine de la silice des m taux lourds du monoxyde de carbone des oxydes d azote des ald hydes ou d autres substances toxiques ou dangereuses pouvant causer la mort ou d...

Page 6: ...ted piping electrical and control systems used and maintained in the boiler room Le terme syst me de br leur chaudi re utilis dans ce manuel signifie tout quipement m canique ou lectrique y compris la...

Page 7: ...esting Controls 16 17 Initial Cleaning Steam Boilers 17 Initial Cleaning Water Boilers 17 18 Water Boiler Operation 18 Boiler Water Treatment 18 pH or Alkalinity Test 18 Warnings about Frequent Water...

Page 8: ...ombustion efficiency of over 80 This manual gives the necessary information for the proper installation operation maintenance and service of units For special installation problems contact Burnham Com...

Page 9: ...um capacity and will light off and have stable and consistent combustion On installations where a natural draft stack is used causing high breeching drafts the boiler locking blade damper on boilers e...

Page 10: ...altitude installations above 1 000 ft An adjustment of 3 5 per 1 000 ft of elevation is recommended 6 LOCATION OF ASME STAMPING DATA The ASME stamping data is located as follows 1 Series 4FH Sizes 63...

Page 11: ...the boiler warms up If formation of condensate persists the low limit should be adjusted upward until condensate no longer forms Water boilers and low pressure steam boilers must have a set LFH at 12...

Page 12: ...es in the boiler metal These stresses can cause damage to the boiler by loosening tubes or in more severe instances can crack tube sheet ligaments furnaces or waterlegs B If temperature differentials...

Page 13: ...MANUAL 9 RELIEF VALVES Boiler relief valves are normally shipped loose and have been properly sized for your boiler The aggregate capacity of the relief valves as stamped on the valve rating plates mu...

Page 14: ...14 FIGURE 4 TS 71 130 D INSTALLATION INSTRUCTIONS FIGURE 3 TS 71 176 B...

Page 15: ...15 TS 71 131 D FIGURE 5 TS 3 101 4 INSTALLATION INSTRUCTIONS FIGURE 6...

Page 16: ...control Avant que l installation de la chaudi re soit consid r e comme termin e v rifier le fonctionnement de ses dispositifs de contr le en particulier les interrupteurs bas niveau d eau et le contr...

Page 17: ...afety relief valve using extreme care to avoid damaging it A Check Operating Control Raise and lower operating control setting as required to start and stop burner B Warning Check High Limit Control J...

Page 18: ...WATER TREATMENT Boiler water treatment will help maximize the effectiveness and prolong the life of pressure vessels The general objectives of boiler water treatment are A Remove corrosive gases from...

Page 19: ...chaudi re par l oxyg ne provoque la corrosion des composants en fer et en acier et peut mener une d faillance La garantie standard de Burnham ne couvre pas les probl mes caus s par la contamination de...

Page 20: ...emperature to increase even if the gauge pressure is 0 It is better to allow the entire system to cool gradually never force cool the boiler as damage can also be inflicted due to thermal shock G When...

Page 21: ...rbulator replacement is from the front smokebox Turbulators should be installed and removed from the front of the boiler only Series 4FH All 4FH Series boilers come equipped with turbulators in all th...

Page 22: ...to solder joints on bellows and float when this type of control is used Check the float for evidence of collapse and check mercury bulb where applicable for mercury separation or discoloration DO NOT...

Page 23: ...at the end of heating season Drain off boiler water until it runs clear while holding the boiler temperature between 180 and 200 F Then refill to top of gauge glass B Water Boilers Since a water boile...

Page 24: ...ion Safety Controls Flame Failure Weekly Operator If flame display installed read and log for both pilot and main flames notify service organization if readings are very high very low or fluctuating r...

Page 25: ...ition Interlock Annually Service Technician Refer to burner instructions Low Fire Start Interlock Annually Service Technician Refer to burner instructions Automatic Changeover At Least Annually Servic...

Page 26: ...26...

Page 27: ...27...

Page 28: ...Product under conditions varying materially from those under such Products is usually tested under industry standards as of the shipment time C Any damage to the Product due to abrasion erosion corro...

Reviews: