![Burley 4111-R Installation, Servicing & User Instructions Download Page 18](http://html1.mh-extra.com/html/burley/4111-r/4111-r_installation-servicing-and-user-instructions_2832669018.webp)
17
Glass
Outlet Grille
Combustion
Air inlets
If you have any questions or the appliance is not operating correctly, phone the Burley help-line
BEFORE you leave the installation.
If the appliance is not fitted in strict accordance with these instructions, Burley cannot be held
responsible for any damage caused and reserve the right to charge for any corrective work.
Note: When lighting the fire from very cold, it may sometimes switch itself off after about 1 min.
This is the very sensitive oxygen depletion circuit proving itself and is normal. Wait for 1 minute and
relight fire. To avoid this happening it is possible to leave the pilot alight at all times.
11.0 Fireguards
A fireguard is not supplied with this appliance; however it is recommended that a fireguard to BS6539
or BS6778 is fitted if the fire is to be used in the presence of young children, the elderly and the infirm.
The glass screen acts as a fireguard and also directs the combustions products through the safety
catalyst. The appliance must not be operated with the glass removed.
12.0
Instruct the User
It is important to hand these instructions to the user for safe keeping and future reference.
The user shall be instructed how to fully operate the appliance, remotely and manually and shown how
to adjust the thermostat for desired comfort levels.
The user shall also be made aware of the precautions to prevent blockage of any purpose made room
ventilation, and the need to keep soft furnishings away from the appliance.
The outlet grille and glass on the appliance are working surfaces. On no account should these be
covered or obstructed. The air inlets should also be kept clear.
The user shall be made aware of the need to operate the appliance safely in accordance with sections
8-12 of the instructions and of the need for regular servicing and maintenance (section 13).
The user shall be informed of the need for at least an annual service and the importance of returning
the guarantee card.
The installer section of the guarantee card must be filled in fully to validate the
warranty.
Advise that a fireguard to BS6539 or BS6778 should be used for the protection of the elderly, the
infirm or children.
Summary of Contents for 4111-R
Page 27: ...26...