background image

 

24 

3.

 

Burley Appliances Ltd - Domestic Guarantee Conditions 

We  pride  ourselves  on  the  quality  of  service  we  deliver  to  our  customers  and  all  Burley  Appliances’ 
products  carry  a  fully  inclusive  12-month  parts  and  labour  guarantee.  This  guarantee  is  extended  by 
another 12 months free of charge provided that your appliance is registered with us within two weeks 
of installation and that it is serviced by a Gas Safe™ registered installer (formerly CORGI) at the end of 
the  first  year.  What  the  guarantee  cannot  cover  is  problems  caused  by  incorrect  installation  or 
servicing, or any work carried out by non- Gas Safe™ registered installer (formerly CORGI). 
 
We undertake that if within 12 months of the date of purchase, your fire or any part thereof is proved 
to  be  defective  by  reason  of  faulty  workmanship  or  materials,  we  will  at  our  discretion  repair  or 
replace the same free of any charge for labour, materials or carriage subject to condition that: 

 

All gas appliances are installed to the latest Gas Installation regulations by a qualified Gas Safe™ 

registered  installer  (formerly  CORGI)  and  connected  to  the  correct  gas  type  and  pressure  as 
stated on the rating plate attached to the equipment. 

 

The  fire  is  fitted  in  a  room  with  the  following  minimum  dimensions  2.5Kw  =  30m

3

  /  3.5Kw  = 

40m

3

 / 4.2Kw = 50m

3

 

 

A wall vent is installed not less than 1 meter away from the fire allowing 100cm

2

 of free air. 

 

You have the fire serviced by a Gas Safe™ registered installer (formerly CORGI) within the first 

year (as with all gas products, every gas appliances must be serviced every year). 

 

The appliance has not been subject to misuse, accident, or repaired or fitted by anyone other 

than Gas Safe ™ registered installer (formerly CORGI) or our own engineer. 

 

The appliance has been used solely for domestic purposes and is on domestic premises i.e. not 

for commercial or trade use. 

 

The appliance has been used solely in accordance with the instruction book. 

Any in guarantee work carried out by Burley Appliances will be charged for if the fault is caused by 
incorrect pressure or gas, incorrect installation, operator error, neglect or abuse. 

All  guarantee  cover  is  instantly  and  permanently  cancelled  if  a  non-  Gas  Safe™  registered  installer 
(formerly CORGI) person carries out any installation or servicing. 

Exclusions 

This guarantee 

does not

 cover: 

 

Damage  resulting  from  external  transportation,  improper  use  or  neglect,  the  replacement  of 
any light bulbs or removable parts of glass or plastic. 

 

Costs incurred for calls to put right an appliance, which is improperly installed. 

 

Appliances that are the subject of rental agreements. 

 

EC Countries - the standard guarantee is applicable but is subject to the owner's responsibility 
and cost, to ensure the appliance meets the standards set by the country to which the product 
is taken.  

Any appliance or defective part replaced shall become the Company's property 

Service Calls are made between 09.30 am and 04.30 pm Monday - Friday.  

This guarantee is in addition to your statutory and other legal rights. 

Proof of purchase will be required as will be a copy of the Gas Safe ™ registered installer (formerly 
CORGI) installer notice. 

 
© Burley Appliances Ltd 2018 
 
 
 

Summary of Contents for 4111-R

Page 1: ...THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 E mail info burley co uk web www burley co uk G4111InstUser G20 31 Issue March 2018...

Page 2: ...mg kWh NOx 1 APPLIANCE DATA Refer to the appliance data badge this is located on a hinge out plate ENSURE THAT THE LOCAL CONDITIONS OF USE CORRESPOND TO THE INFORMATION ON THE DATA BADGE Natural Gas G...

Page 3: ...ould cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the pilo...

Page 4: ...er unit to its original position REPLACE THE HEAT SHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat sh...

Page 5: ...ds then turn slowly anticlockwise to the ignition position A click will be heard and the pilot should light If it does not repeat the operation a few times to purge any air in the pipes Continue to ho...

Page 6: ...he control lever to the top of its travel 6 The off position on the side of the fire may not correspond exactly with the control lever This is only intended as an indication 1 6 Battery Replacement Be...

Page 7: ...lso be in accordance with the relevant parts of local and national building regulations Failure to have the fire fitted by a qualified person nullifies ALL guarantees 3 2 With the exception of the bot...

Page 8: ...t size to carry the demand of this appliance and the demand of other appliances installed To prevent unacceptable pressure losses no more than 1 5m of 8mm pipe should be used 4 2 Decide on the gas sup...

Page 9: ...st ensure that clearance for the trim is made as this protrudes below the bottom of the appliance Due to the low temperatures at floor level it is acceptable to use material such as wood for the heart...

Page 10: ...ealants and adhesives is not recommended as these can give off smells when heated and stain fireplaces Always use one or a combination of the methods detailed Method one Using the eye bolt and cable f...

Page 11: ...No 10 wood screws to fix the appliance in place Method Four This is ONLY for use where there is a cavity box fitted The appliance and cavity box both have holes in their outside flange and can be scr...

Page 12: ...be removed within the enclosure and any paper backed plaster board on the wall face location shall be protected or replaced with plaster or rigid non combustible insulating board If installing on the...

Page 13: ...gas supply pipe to the 8 mm compression fitting on the inlet pressure test point elbow The complete installation shall be checked for gas tightness using an approved method 7 1 8 Complete the assembly...

Page 14: ...assembly 7 2 8 With the fire box fitted securely into the opening refit the burner control assembly 7 2 9 Connect the gas supply pipe to the 8 mm compression fitting on the inlet pressure test point e...

Page 15: ...lat and slowly push back until it touches the protruding ends of the rear log piece Fig 9 Figure 9 8 1 3 Using photo to identify the correct Y shaped log place log on the left hand side of the fuel be...

Page 16: ...visible through the window in the printing 8 2 2 The top part of the glass panel should be engaged under the catalyst vent panel The vent panel shall then be fixed using the 3 screws Fig 3 8 3 Fitting...

Page 17: ...0 COMMISSIONING AND OPERATION YOU MUST COMPLETELY ASSEMBLE THE FIRE INCLUDING THE GRILL BEFORE COMMISSIONING BURLEY APPLIANCES IS THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVERY SINGLE GAS FI...

Page 18: ...yst The appliance must not be operated with the glass removed 12 0 Instruct the User It is important to hand these instructions to the user for safe keeping and future reference The user shall be inst...

Page 19: ...e ceramic fuel bed components These components are extremely fragile Examine the condition and check for signs of damage or cracking Replace if necessary Clean these components with a soft brush and o...

Page 20: ...recommend the following on an annual basis Check for combustion product leakage It is important that the products of combustion produced by this appliance all pass through the two catalysts A very sma...

Page 21: ...9 13 10 13 11 Spark Ignition lead 13 12 13 13 Catalyst CAT4001 X 2 USE ONLY GENUINE REPLACEMENT PARTS In certain cases depending on the fault and the part or parts to be replaced Burley Appliances may...

Page 22: ...est must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least 15 min...

Page 23: ...ult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filter...

Page 24: ...ant to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can...

Page 25: ...st year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than Gas Safe registered i...

Page 26: ...ling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up but are...

Page 27: ...26...

Page 28: ...fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk Email...