52
Electrical installation
Type 8098 FLOWave L
5. Loosen the nut of the cable gland.
6. Do not remove the nut of a stainless steel
M20x1.5 cable gland. The nut of a stainless steel
M20x1.5 cable gland cannot be removed.
7.
Turn the nut until the stop. If you turn beyond the
stop, the cable gland unscrews from the device
and the device is no longer tight.
8. Remove the blind plug of the cable gland and
store the blind plug in a safe and clean place.
9. Put the cable through the cable gland as shown
in the figure.
10. Use a size 22 hexagonal key to tighten the cable
gland to a torque of 5 Nm (3.7 ft·lbf).
11. Attach each cable to the functional earth plate.
The shield must be in contact with the functional
earth plate.
12. Put the functional earth plate in its original place.
13.
Use a size 10 hexagonal key to tighten the
2 screws of the functional earth plate to a torque
of 0.2 Nm (0.15 ft·lbf).
2 screws
Functional earth
IT IS NOT MANDATORY TO
CONNECT THE DEVICE TO A
PROTECTIVE EARTH - MEANT
FOR FUTURE USE
English