16
8175
ENGLISH
INSTALLATION
N
L1
+
-
-
+
4
3
2
1
115/230 VAC
N
L1
REL1
REL2
N
L1
+
-
-
+
4
3
2
1
115/230 VAC
N
L1
REL1
REL2
WIRING OF THE 115/230 VAC VERSION
Remove the cover via the screws on the front display and pull the cable through the
cable gland and wire according to one of the pin assignment diagrams below.
The electronics within the 8175 allows a sourcing or sinking PLC to be connected.
Position A (Fig 3.5) provides a sourcing configuration and Position B (Fig 3.6) a
sinking configuration.
●
Do not open and wire the transmitter with the power supply
connected.
●
Ensure that the power supply switch is selected for the appropriate
voltage 115VAC or 230 VAC.
The connection for relays 1 and 2 are identical to that of the 18-32VDC on the
previous page.
Fig. 3.8 Pin assignment, Position A
Fig. 3.9 Pin assignment, Position B
SW 2,
Position A
SW 2,
Position B
Fuse - 5A
Fuse - 5A
PLC/control valve/
positioner 4-20mA
PLC/control valve/
positioner 4-20mA
Power Supply
switch
Fuse - 250 mA T
Fuse - 250 mA T
Red wire
Black wire
Green&yellow
wire
Red wire
Black wire
Green&yellow
wire
Summary of Contents for 8170
Page 1: ...8175 8170 ULTRASONIC LEVEL TRANSMITTER COMPACT AND SEPARATE VERSIONS Instruction Manual...
Page 63: ...63 8175 ENGLISH INFORMATION 8170 Sensor in mm SW50 81 108 26 3 80...
Page 68: ...68 8175 ENGLISH ANNEX...
Page 69: ...8175 8170 TRANSMETTEUR DE NIVEAU A ULTRASONS VERSIONS COMPACTE ET SEPAREE Manuel d utilisation...
Page 131: ...63 8175 FRANCAIS INFORMATION Capteur 8170 en mm SW50 81 108 26 3 80...
Page 136: ...68 8175 FRANCAIS ANNEXES...
Page 199: ...63 8175 DEUTSCH INFORMATIONEN Sensor 8170 in mm SW50 81 108 26 3 80...
Page 204: ...68 DEUTSCH INFORMATIONEN 8175...