Page 33
Procedure to adjust the flow rate setting:
1. Press and hold upper right hidden switch until the
display reads
UNITS
. Release switch. Continue to
press and release switch until the display reads
L SPRY OZ/M
. The number represents what the
brewer thinks is the flow rate of the sprayhead in
ounces per minute.
2. If the actual flow rate of the sprayhead is known,
but is different than the number on the display,
use the
(-)
and
(+)
to enter the correct flow rate
in ounces per minute.
3. When finished, press and release
DONE
. This saves
the new setting and advances to
R SPRY OZ/M.
When finished setting the right side, press and
release
DONE
to advance to
next function screen,
L BYPS OZ/M.
Another alternative is to press and
release either ON/OFF switch located on the front
switch panel to exit
R SPRY OZ/M
function and
return to the
MAIN SCREEN.
BYPASS OZ/M
This function allows the operator to view or to enter
the actual flow rate coming out of the bypass nozzle.
This is
NOT
used to change the actual flow rate, but to
tell the internal controller how fast the water is flowing.
The unit of measure is ounces per minute.
SPRAY OZ/M (cont.)
P2721
L BYPS OZ/M: XXX
(-)
DONE
(+)
Procedure to adjust the flow rate setting:
1. Press and hold upper right hidden switch until
display reads
UNITS
. Release switch. Continue
to press and release switch until display reads
L
BYPASS OZ/M
. The number represents what the
brewer thinks is the flow rate of the bypass valve
in ounces per minute.
2. If the actual flow rate of the bypass valve is known,
but is different than the number on the display,
use the
(-)
and
(+)
to enter the correct flow rate
in ounces per minute.
3. When finished, press and release the
DONE
. This
saves the new setting and advances to
R BYPS
OZ/M
. When finished setting right side, press and
release
DONE
to advance to next function screen,
CALIBRATE FLOW.
Another alternative is to press
and release either ON/OFF switch located on the
front switch panel to exit the
BYPASS OZ/M
func-
tion and return to the
MAIN SCREEN.
CALIBRATE FLOW
This function allows the operator to enter the actual
flow rate of the sprayhead and the bypass for each
side of the brewer by dispensing both separately for
one minute. The volumes are then entered in ounces
per minute (OZ/M).
Procedures to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, be-
neath the funnel on the side of the brewer to be
calibrated.
2. Press and hold upper right hidden switch until the
display reads
UNITS
. Release switch. Continue
to press and release switch until display reads
CALIBRATE FLOW ?
.
3. Press and release
YES
to advance to the
SPRAY
HEAD CAL?
function screen. (Pressing
NO
in the
CALIBRATE FLOW
screen will advance to the next
function screen,
BREW COUNTERS).
4. Press and release
YES
. The display should read
CONTAINER READY?
If the container is under
the funnel, press
YES.
The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the BREW switch on the side to
be calibrated. The display should read
CALIBRATE
SPRAY .. 60 SEC TO FINISH.
The 60 second timer
on the display will count down to zero. When the
counter reaches zero, the display will change to
ENTER OZ,
along with a number signifying ounces
per minute.
6. Measure the amount of water in the container
and using the
(-)
or
(+)
, adjust the amount on the
display to match the amount in the container. Then
press
DONE
.
7. The display should now read
NEW L
or
R SPRY
FLOW
, along with the correct flow rate of the
sprayhead in ounces per minute. After about 5
seconds, the display will return to the
CALIBRATE
FLOW
screen.
8. To exit the
CALIBRATE FLOW
program, press
NO
PROGRAMMING THE BREWER (cont.)
29877-3 062005