Page 26
FIG. 30 MASTER ON/OFF SWITCH - MODEL RT
FIG. 29 MASTER ON/OFF SWITCH - MODEL OT
FIG. 31 MASTER ON/OFF SWITCH WIRING
SERVICE (cont.)
Master ON/OFF Switch
Location:
The Master ON/OFF switch is located in the base, at
the left rear, FIG.s 29 & 30.
Test Procedure:
1. Disconnect the brewer from the power source
and remove the wires from all terminals of the
Master ON/OFF switch.
2. Check for continuity across the two terminals on
the switch at L1 BLK and BLK to Main Harness
when it is held in the lower position, Fig. 25.
Check for continuity across the two terminals on
the switch at L2 RED and RED to Main Harness
when it is held in the lower position.
Continuity must not be present across these
terminals in the upper position.
If continuity is present as described, reconnect the
wires, the switch is operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove all wires from the switch terminals.
2. Remove the two screws from the outside of the
base and gently push the switch through the
opening.
3. Locate the new switch into the opening and se-
cure with screws removed in step 2.
4. Refer to FIG. 31 when reconnecting the wires.
Incoming Power Supply
L1 - BLK
L2 - RED
Main Wiring harness
BLK
RED
P1687
P1688
P3955
32440 010308
Part II
Summary of Contents for OL
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 27: ...Part I ...
Page 48: ... BUNN HOUSINGS PANELS ModelOL OL RL OT RT _ b _ _ 16 15 14 RevisedDecemberl999 Part I ...
Page 50: ... BUNN HOUSlNGS PANELS ModelRL D I a OL RL OT RT 2 P1649 6 RevisedDecember1999 Part I ...
Page 54: ... BUNN HOUSlNGS PANELS ModelRT OL RL OT RT P1651 IO RevisedDecember1999 Part I ...
Page 60: ...BUNN TANK COMPONENTS ModelsOT RT OL RL OT RT P1653 16 RevisedDecemberl999 Part I ...
Page 62: ...BUNN STRAlNER ModelsOL RL OL RL OT RT 9 8 IO 7 P1654 18 RevisedDecember1999 Part I ...
Page 68: ...BUNN WARMER ASSEMBLIES ModelsOL OT OL RL OT RT P1657 24 RevisedDecember1999 Part I ...
Page 72: ......
Page 73: ......
Page 76: ...ELECTRICAL OPERATING CONTROLS ModelRL OL RL OT RT 32 RevisedDecember1999 Part I ...
Page 78: ...Part I ...
Page 82: ...Part I ...
Page 86: ...BUNN 8 FUNNELS BASKETS OL RL OT RT 47 RevisedDecember1999 Part I ...
Page 90: ......
Page 92: ......
Page 170: ...44 BUNN OL RL OT RT FUNNELS BASKETS P1663 1 2 3 6 4 5 7 9 6 7 1 8 10785 010708 Part II ...
Page 174: ......