Page 17
FIG. 8 WARMERS
FIG. 9 WARMERS
FIG. 10 WARMER WIRING
SERVICE (cont.)
Warmer(s)
OT:
Brew Station & Upper
RT:
Left Rear, Left Front, Brew Station, Right Rear & Right
Front
Location:
OT: One of the warmers is beneath the brew funnel
and the other is on the top lid, FIG. 8.
RT: These warmers include the one beneath the
brew funnel, the ones on the right and left of the brew
station, and the one above and to the left and right of
the brew station as viewed from the front, FIG. 9.
Test Procedure:
1. Once the switch has been tested and switch failure
has been eliminated, proceed as follows.
2. Disconnect the brewer from the power source and
remove the #4-40 screws attaching the warmer
being tested.
3. Lift the warmer assembly from the brewer and
invert the warmer making the wire terminals ac-
cessible for testing.
4. Check for continuity from the switch to the black
wire at the warmer element.
If continuity is present as described, proceed to #5.
5. Check for continuity from the wire terminal of the
white or red wire to the splice or indicator lamp
using the chart below.
If continuity is present as described, proceed to #6.
If continuity is not present as described, refer to the
Wiring Diagrams and check the brewer wiring har-
ness.
6. Check for continuity across the two terminals on
the warmer.
If continuity is present as described, the warmer is
operating properly.
If continuity is not present as described, replace the
warmer.
Removal and Replacement:
1. Remove the #4-40 slotted-head screws holding
the warmer to the brewer
2. Lift the warmer assembly from the brewer.
3. Disconnect both wires from the warmer.
4. Refer to FIG. 10 when reconnecting the wires.
5. Place the new warmer into the brewer and se-
curely attach it using the #4-40 screws.
MODEL
OT Upper
WHI OR RED
to Indicator Lamp
OT Brew Station
WHI OR RED
to Indicator Lamp
to Terminal Block
RT Left Rear
WHI OR RED
to Terminal Block
to Brew Station Warmer
RT Left Front
WHI OR RED
to Indicator Lamp
to Terminal Block
RT Brew Station
WHI OR RED
to Timer P2
to Left Rear Warmer
RT Right Front
WHI OR RED
to Right Rear Warmer
to Indicator Lamp
RT Right Rear
WHI OR RED
to Right Front Warmer
WHI or RED (see below)
BLK to Warmer Switch
P1687
P1688
P1692
32440 070700
Part II
Summary of Contents for OL
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 27: ...Part I ...
Page 48: ... BUNN HOUSINGS PANELS ModelOL OL RL OT RT _ b _ _ 16 15 14 RevisedDecemberl999 Part I ...
Page 50: ... BUNN HOUSlNGS PANELS ModelRL D I a OL RL OT RT 2 P1649 6 RevisedDecember1999 Part I ...
Page 54: ... BUNN HOUSlNGS PANELS ModelRT OL RL OT RT P1651 IO RevisedDecember1999 Part I ...
Page 60: ...BUNN TANK COMPONENTS ModelsOT RT OL RL OT RT P1653 16 RevisedDecemberl999 Part I ...
Page 62: ...BUNN STRAlNER ModelsOL RL OL RL OT RT 9 8 IO 7 P1654 18 RevisedDecember1999 Part I ...
Page 68: ...BUNN WARMER ASSEMBLIES ModelsOL OT OL RL OT RT P1657 24 RevisedDecember1999 Part I ...
Page 72: ......
Page 73: ......
Page 76: ...ELECTRICAL OPERATING CONTROLS ModelRL OL RL OT RT 32 RevisedDecember1999 Part I ...
Page 78: ...Part I ...
Page 82: ...Part I ...
Page 86: ...BUNN 8 FUNNELS BASKETS OL RL OT RT 47 RevisedDecember1999 Part I ...
Page 90: ......
Page 92: ......
Page 170: ...44 BUNN OL RL OT RT FUNNELS BASKETS P1663 1 2 3 6 4 5 7 9 6 7 1 8 10785 010708 Part II ...
Page 174: ......