Problem
Equipment will not operate.
Brew cycle will not start.
Probable Cause
1. No power or incorrect voltage
1. No water
2. Water Strainer
3. Flow Control
Remedy
(A) Connect the brewer to the power
source.
(B) Check the terminal block for the
proper voltages.
(C) Check circuit breaker/fuse.
Check plumbing and shut-off
valves.
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer and check
for obstructions. Clear or replace.
(A) Direction of flow arrow must be
pointing away from the solenoid.
(B) Remove the control and check
for obstructions. Clear or replace.
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
• Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-
nel.
• All electric components have 120 volt ac voltage on their terminals. Shorting of terminals or the application
of external voltages may result in equipment failure.
• Intermittent operation of electronic equipment is unlikely. Component failure will normally be permanent.
If an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
• Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
• The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.
• Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
• This brewer is heated at all times unless disconnected from the power source. Keep away from combus-
tibles.
WARNING
• Exercise extreme caution when servicing electrical equipment.
• Disconnect the brewer from the power source when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices
32440 121699
Part II
Summary of Contents for OL
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 27: ...Part I ...
Page 48: ... BUNN HOUSINGS PANELS ModelOL OL RL OT RT _ b _ _ 16 15 14 RevisedDecemberl999 Part I ...
Page 50: ... BUNN HOUSlNGS PANELS ModelRL D I a OL RL OT RT 2 P1649 6 RevisedDecember1999 Part I ...
Page 54: ... BUNN HOUSlNGS PANELS ModelRT OL RL OT RT P1651 IO RevisedDecember1999 Part I ...
Page 60: ...BUNN TANK COMPONENTS ModelsOT RT OL RL OT RT P1653 16 RevisedDecemberl999 Part I ...
Page 62: ...BUNN STRAlNER ModelsOL RL OL RL OT RT 9 8 IO 7 P1654 18 RevisedDecember1999 Part I ...
Page 68: ...BUNN WARMER ASSEMBLIES ModelsOL OT OL RL OT RT P1657 24 RevisedDecember1999 Part I ...
Page 72: ......
Page 73: ......
Page 76: ...ELECTRICAL OPERATING CONTROLS ModelRL OL RL OT RT 32 RevisedDecember1999 Part I ...
Page 78: ...Part I ...
Page 82: ...Part I ...
Page 86: ...BUNN 8 FUNNELS BASKETS OL RL OT RT 47 RevisedDecember1999 Part I ...
Page 90: ......
Page 92: ......
Page 170: ...44 BUNN OL RL OT RT FUNNELS BASKETS P1663 1 2 3 6 4 5 7 9 6 7 1 8 10785 010708 Part II ...
Page 174: ......