PROGRAMMING THE BREWER (cont.)

BREW COUNTERS

  This function allows the operator to track the 

number of brew cycles completed. The number of 

brew cycles on the left side, the right side, and the total 

of both combined can be tracked on DUAL brewers. 

There is one resettable counter, and one life counter 

that is not resettable for SINGLE brewers and three 

resettable counters, and one life counter that is not 

resettable for DUAL brewers.

Procedures to view/reset the brew counters:

1.  Press and hold the upper right hidden switch until 

the display reads UNITS. Release the switch. Con-

tinue to press and release switch until the display 

reads BREW COUNTERS.

2. Pressing NO in this screen will advance to the next 

function.  Press YES to view the first brew counter 

(left side on DUAL brewers). This number repre-

sents the brew cycles initiated since that counter 

was last reset.

BREW COUNTERS?

NO                   YES

LEFT            X XXX

 

NEXT  RESET

SINGLE

BREWERS

DUAL

BREWERS

RIGHT            X XXX

 

NEXT  RESET

L+R              X XXX

 

NEXT  RESET

L+R              X XXX

NEXT

X XXX

 

NEXT  RESET

X XXX

NEXT

EXIT TO

NEXT FUNCTION

SCREEN

3.  To advance to the other counters, press and release 

NEXT. The four counters for DUAL brewers are as 

follows:

 

LEFT - total brews on left side (resettable)

 

RIGHT -  total brews on right side (resettable)

 

LEFT AND RIGHT - total brews on left and right 

sides combined (resettable)

 

LEFT AND RIGHT - total brews on left and right 

sides combined (non-resettable)

4.  To reset any of the counters to zero (except for the 

non-resettable counter), press and release RESET 

when viewing that particular counter's screen.

5.  When finished, press NEXT to advance counter 

screens until the display reads BREW COUNTERS. 

Press and release NO to advance to the next function 

screen, or press  and release the ON/OFF switch 

(either on DUAL brewers) on the front switch panel 

to exit the BREW COUNTERS function and return 

to the MAIN SCREEN.

RESETS LEFT 

COUNTER

RESETS RIGHT 

COUNTER

RESETS BOTH 

LEFT AND RIGHT 

COUNTERs

41342 080108

Summary of Contents for DUAL SH DBC WITH SMART FUNNEL DUAL068000

Page 1: ...DBC W SMART FUNNEL S N DUAL068000 UP PROGRAMMING MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 41342 0000C 4 12 2008 Bunn O...

Page 2: ...ons to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Page 3: ...30 Calibrate Sprayhead Flow 30 Calibrate Bypass Flow 31 Brew Counters View Reset 32 Funnel Detect 33 Service Tools 33 Test Outputs Components 33 Test Switches 34 Test Frequency 34 Factory Defaults Re...

Page 4: ...into the funnel and allows for the brewer to automatically set itself to what is read from the funnel handle LAST ON TIME During a pulse brew this is the time set for the second on time and each alte...

Page 5: ...tches are used There are five of these switches that will be used for the setup of the brewer 1 2 3 4 5 1 symbol upper right of the BUNN logo This is used to access the programming mode and is also us...

Page 6: ...s function screen and return to the MAIN SCREEN on the display PROGRAMMING THE BREWER The programming of the brewer is divided into two levels There is one function in Level 1 All other functions are...

Page 7: ...REINFUSION TIMES and DRIP OUT TIMES METHOD 3 Not using a Smart Funnel and or a G9 2T DBC or MHG Grinder This allows the operator to enter ONE set of brew ing parameters for each side on DUAL brewers i...

Page 8: ...CIPE COPY SETTINGS NO YES LEFT RIGHT NO YES Continue to D Cycles thru left side program constants Continue to E FULL 1 2 1 4 SET ALL 3 BATCHES both sides for DUAL brewers ARE YOU SURE NO YES 3 BATCHES...

Page 9: ...ES DONE NO YES 1st OFF LAST X XX X XX X XX TRANSFER COMPLETE ENABLE ADS NO DONE YES SET TEMP 200 F DONE SET READY 195 F DONE 0 REFILL 155 DONE L SPRY OZ M XX X DONE R SPRY OZ M XX X DONE Continue to F...

Page 10: ...N NEXT OFF RIGHT BREW VALVE ON NEXT OFF RIGHT BYPASS ON NEXT OFF RIGHT FUNEL LOCK ON NEXT OFF REFILL VALVE ON NEXT OFF HEATER CONTACTOR ON NEXT OFF SPRAY HEAD CAL NO YES BYPASS CAL NO YES CONTAINER RD...

Page 11: ...onstoredelsewhere so that the machine can be reprogrammed Procedure for modifying units of measure 1 Press and hold upper right hidden switch until the display reads UNITS Release switch Press and rel...

Page 12: ...6 If YES was selected the display should now read X X HRS IDLE This screen allows the opera tor to set the amount of time the brewer is not in use before nap mode engages Using and adjust the idle ti...

Page 13: ...ndividually to provide optimum brewing quality P2415 BREW OZ XX X DONE BYPASS XX X DONE 3 BATCHES DONE NO YES PROGRAMMING THE BREWER cont DUAL BREWERS only Procedure for Setting the Recipe NOTE Before...

Page 14: ...METHOD 17 If setting pulse brew by MANUAL METHOD en tering known times press MANUAL then NEXT and proceed with the setup instructions for SET PULSE BREW MANUAL METHOD SET DRIP TIME Refer to SET DRIP...

Page 15: ...ion the RECIPE CARD vertically so that the top end of the CHIP is beneath the left side funnel sensing coil 3 AfterashortpausethedisplaywillreadCARDCON TAINS RECIPE FOR then will change to COFFEE NAME...

Page 16: ...rwillperform in the same capacity as a standard Bunn Single Dual Brewer The instructions for programming the NO NAME settings are on the following pages The same steps are followed for setting the rec...

Page 17: ...all the brew settings for that particular coffeename Whenfinished thedisplaywillreturn to the coffee name just viewed 4 To see settings again press SHOW To advance to the next coffee name press NEXT 5...

Page 18: ...essanotherbatchsizeandrepeat step 5 for that size for each batch size to be modi fied Continue setting all batch sizes 7 When finished setting all batch sizes press and release DONE The display should...

Page 19: ...l be blinking Press and release the batch size to be modified 7 Using and set the amount of bypass water percentage to be dispensed around the grounds for that particular batch size 8 Whenfinished pre...

Page 20: ...LTERNATES UNTIL BREW CYCLE IS COMPLETED PRE INFUSION REMAINING ON ON TIME OFF TIME OFF TIME OFF TIME OFF TIME ON TIME ON TIME Modifying pulse brew Range 1st on time off to 4 minutes Off time off to 4...

Page 21: ...ME MODIFY SHOW NEXT THAT WAS THE LAST RECIPE WHEN THE LAST COFFEE NAME IN BREWER S MEMORY IS DISPLAYED PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ ADVANCES TO ALL OTHER COFFEE NAMES PROGRAM...

Page 22: ...the indicator light Repeat step 2 for each batch size to be set 4 When finished setting all batch sizes press done This will display the 1st OFF and LAST times for 5 seconds then advance to 3 BATCHES...

Page 23: ...aywillshow thethreetimesjustenteredforthatbatchsize After a 5 second delay the display will read 3 BATCHES DONE 8 If other batch sizes need to be modified press NO 9 Press a different batch size and r...

Page 24: ...A batch light should also be blinking 10 Using the and set the amount of time from when the brew solenoid shuts off to when drip out occurs for that batch size NOTE Set to OFF to prevent funnel locks...

Page 25: ...leasetheswitch Con tinue to press and release switch until the display reads COPY SETTINGS ASSIGN RECIPES This function allows for assigning a coffee name other than NO NAME to the BREW switch Procedu...

Page 26: ...ewer with an AD CARD This message will be displayed when the brewer is not in use Procedure to Enable Disable Ads 1 Press and hold upper right hidden switch until the display reads UNITS Release switc...

Page 27: ...idden switch until the display reads UNITS Release switch Continue to press and release switch until the display reads SET READY 2 To adjust the ready temperature press the button to decrease or to in...

Page 28: ...OFF switch located on the front switch panel to exit R SPRY OZ M function and return to the MAIN SCREEN SPRAY OZ M SINGLE BREWERS Thisfunctionallowstheoperatortoviewortoenter the actual flow rate comi...

Page 29: ...IN SCREEN BYPASS OZ M DUAL BREWERS Thisfunctionallowstheoperatortoviewortoenter the actual flow rate coming out of the bypass nozzle This is NOT used to change the actual flow rate but to telltheinter...

Page 30: ...SEC TO FIN ISH The 60 second timer on the display will count down to zero When the counter reaches zero the display will change to ENTER OZ along with a number signifying ounces per minute 6 Measure...

Page 31: ...When the counter reaches zero the display will change to ENTER OZ SINGLE brewers LEFT or RIGHT OZ DUAL brewers along with a number 7 Measure the amount of water in the container and using or adjust t...

Page 32: ...st reset BREW COUNTERS NO YES LEFT X XXX NEXT RESET SINGLE BREWERS DUAL BREWERS RIGHT X XXX NEXT RESET L R X XXX NEXT RESET L R X XXX NEXT X XXX NEXT RESET X XXX NEXT EXIT TO NEXT FUNCTION SCREEN 3 To...

Page 33: ...not correctly situated in the rails If this function is activated and a brew cycle is attempted with the funnel not properly situated the display will read FUNNEL NOT IN PLACE until one is in place 5...

Page 34: ...e MAIN SCREEN Procedure to test switches Thisfunctionallowstheoperatortotesttheopera tion of the individual switches on the front panel 1 Place brew funnel s into rails on the brewer both sides on DUA...

Page 35: ...TANK HEATRS ON NEXT OFF HEATER CONTACTOR ON NEXT OFF BREW VALVE ON NEXT OFF BYPASS ON NEXT OFF FUNNEL LOCK ON NEXT OFF SINGLE BREWERS DUAL BREWERS EXIT TO NEXT FUNCTION SCREEN TEST SWITCHES NO YES NOT...

Page 36: ...and ad messages Factory set default values will replace all previous settings EXIT EXIT REPLACE WILL REPLACE ALL BREW SETTINGS ARE YOU SURE NO YES FACTORY DEFAULTS NO YES ThermoF SoftHeat DONE SEL BRE...

Reviews: