PROGRAMMING THE BREWER (cont.)

REFILL - Range: 20 to 230

  This function allows the operator to adjust the 

sensitivity of the refill circuit. This is mainly a trouble-

shooting feature. Water in different geographical loca-

tions can have different conductivities. By adjusting 

the sensitivity of the refill circuit, this will allow the 

brewer to operate under various water conditions.

Procedure to set the sensitivity threshold of the 

refill circuit:

NOTE: Make sure the water in the tank is touching 

the refill probe.

1.  Press and hold upper right hidden switch until the 

display reads UNITS. Release switch.  Continue to 

press and release switch until the display reads 

REFILL and shows a number on both sides of the 

word.

2.  To adjust the threshold setting, press (-) to de-

crease, or (+) to increase the setting.

NOTE: Always make sure that the number on the right 

is larger than the number on the left when water is in 

contact with the refill probe in the tank.

3.  When finished, press and release DONE. This saves 

the new setting and advances to the next function 

screen:

  SPRY OZ/M (SINGLE brewers)

 

L SPRY OZ/M (DUAL brewers). Another alternative 

is to press and release the ON/OFF switch (either on 

DUAL brewers) located on the front switch panel 

to exit REFILL and return to the MAIN SCREEN.

Procedure to set ready temperature:

1.  Press and hold upper right hidden switch until the 

display reads UNITS. Release switch.  Continue to 

press and release switch until the display reads 

SET READY.

2.  To adjust the ready temperature, press the (-) 

button to decrease, or (+) to increase the ready 

temperature.

3.  When finished, press and release DONE to save 

the new setting, exit the SET READY function and 

advance to the next function screen, REFILL. 

Another alternative is to press and release the 

ON/OFF switch (either on DUAL brewers) located 

on the front switch panel to exit the SET READY 

function and return to the MAIN SCREEN.

2.  To adjust the brew temperature, press (-) to de-

crease or (+) to increase the brew temperature.

3.  When finished, press and release DONE to save 

the new setting, exit the SET TEMP function and 

advance to the next function screen,  SET READY. 

Another alternative is to press and release  the ON/

OFF switch (either on DUAL brewers) located on 

the front switch panel to exit the SET TEMP func-

tion and return to the MAIN SCREEN.

SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)

 

This function allows the operator to set the mini-

mum temperature allowable to start a brew cycle. The 

range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) 

of the SET TEMP. The water must be at the SET READY 

temperature or higher for the display to indicate READY 

TO BREW. If brew lockout is enabled, the brewing pro-

cess will not start below this READY temperature.

NOTE: The upper limit for SET READY temperature 

is 2˚F (-1.7°C) less than the water temperature (SET 

TEMP) setting.

SET READY: XXX°

 (-)  DONE  (+)

XXX REFILL -> XXX

 (-)  DONE  (+)

SET TEMP (cont.)

41342 080108

Summary of Contents for DUAL SH DBC WITH SMART FUNNEL DUAL068000

Page 1: ...DBC W SMART FUNNEL S N DUAL068000 UP PROGRAMMING MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 41342 0000C 4 12 2008 Bunn O...

Page 2: ...ons to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Page 3: ...30 Calibrate Sprayhead Flow 30 Calibrate Bypass Flow 31 Brew Counters View Reset 32 Funnel Detect 33 Service Tools 33 Test Outputs Components 33 Test Switches 34 Test Frequency 34 Factory Defaults Re...

Page 4: ...into the funnel and allows for the brewer to automatically set itself to what is read from the funnel handle LAST ON TIME During a pulse brew this is the time set for the second on time and each alte...

Page 5: ...tches are used There are five of these switches that will be used for the setup of the brewer 1 2 3 4 5 1 symbol upper right of the BUNN logo This is used to access the programming mode and is also us...

Page 6: ...s function screen and return to the MAIN SCREEN on the display PROGRAMMING THE BREWER The programming of the brewer is divided into two levels There is one function in Level 1 All other functions are...

Page 7: ...REINFUSION TIMES and DRIP OUT TIMES METHOD 3 Not using a Smart Funnel and or a G9 2T DBC or MHG Grinder This allows the operator to enter ONE set of brew ing parameters for each side on DUAL brewers i...

Page 8: ...CIPE COPY SETTINGS NO YES LEFT RIGHT NO YES Continue to D Cycles thru left side program constants Continue to E FULL 1 2 1 4 SET ALL 3 BATCHES both sides for DUAL brewers ARE YOU SURE NO YES 3 BATCHES...

Page 9: ...ES DONE NO YES 1st OFF LAST X XX X XX X XX TRANSFER COMPLETE ENABLE ADS NO DONE YES SET TEMP 200 F DONE SET READY 195 F DONE 0 REFILL 155 DONE L SPRY OZ M XX X DONE R SPRY OZ M XX X DONE Continue to F...

Page 10: ...N NEXT OFF RIGHT BREW VALVE ON NEXT OFF RIGHT BYPASS ON NEXT OFF RIGHT FUNEL LOCK ON NEXT OFF REFILL VALVE ON NEXT OFF HEATER CONTACTOR ON NEXT OFF SPRAY HEAD CAL NO YES BYPASS CAL NO YES CONTAINER RD...

Page 11: ...onstoredelsewhere so that the machine can be reprogrammed Procedure for modifying units of measure 1 Press and hold upper right hidden switch until the display reads UNITS Release switch Press and rel...

Page 12: ...6 If YES was selected the display should now read X X HRS IDLE This screen allows the opera tor to set the amount of time the brewer is not in use before nap mode engages Using and adjust the idle ti...

Page 13: ...ndividually to provide optimum brewing quality P2415 BREW OZ XX X DONE BYPASS XX X DONE 3 BATCHES DONE NO YES PROGRAMMING THE BREWER cont DUAL BREWERS only Procedure for Setting the Recipe NOTE Before...

Page 14: ...METHOD 17 If setting pulse brew by MANUAL METHOD en tering known times press MANUAL then NEXT and proceed with the setup instructions for SET PULSE BREW MANUAL METHOD SET DRIP TIME Refer to SET DRIP...

Page 15: ...ion the RECIPE CARD vertically so that the top end of the CHIP is beneath the left side funnel sensing coil 3 AfterashortpausethedisplaywillreadCARDCON TAINS RECIPE FOR then will change to COFFEE NAME...

Page 16: ...rwillperform in the same capacity as a standard Bunn Single Dual Brewer The instructions for programming the NO NAME settings are on the following pages The same steps are followed for setting the rec...

Page 17: ...all the brew settings for that particular coffeename Whenfinished thedisplaywillreturn to the coffee name just viewed 4 To see settings again press SHOW To advance to the next coffee name press NEXT 5...

Page 18: ...essanotherbatchsizeandrepeat step 5 for that size for each batch size to be modi fied Continue setting all batch sizes 7 When finished setting all batch sizes press and release DONE The display should...

Page 19: ...l be blinking Press and release the batch size to be modified 7 Using and set the amount of bypass water percentage to be dispensed around the grounds for that particular batch size 8 Whenfinished pre...

Page 20: ...LTERNATES UNTIL BREW CYCLE IS COMPLETED PRE INFUSION REMAINING ON ON TIME OFF TIME OFF TIME OFF TIME OFF TIME ON TIME ON TIME Modifying pulse brew Range 1st on time off to 4 minutes Off time off to 4...

Page 21: ...ME MODIFY SHOW NEXT THAT WAS THE LAST RECIPE WHEN THE LAST COFFEE NAME IN BREWER S MEMORY IS DISPLAYED PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ ADVANCES TO ALL OTHER COFFEE NAMES PROGRAM...

Page 22: ...the indicator light Repeat step 2 for each batch size to be set 4 When finished setting all batch sizes press done This will display the 1st OFF and LAST times for 5 seconds then advance to 3 BATCHES...

Page 23: ...aywillshow thethreetimesjustenteredforthatbatchsize After a 5 second delay the display will read 3 BATCHES DONE 8 If other batch sizes need to be modified press NO 9 Press a different batch size and r...

Page 24: ...A batch light should also be blinking 10 Using the and set the amount of time from when the brew solenoid shuts off to when drip out occurs for that batch size NOTE Set to OFF to prevent funnel locks...

Page 25: ...leasetheswitch Con tinue to press and release switch until the display reads COPY SETTINGS ASSIGN RECIPES This function allows for assigning a coffee name other than NO NAME to the BREW switch Procedu...

Page 26: ...ewer with an AD CARD This message will be displayed when the brewer is not in use Procedure to Enable Disable Ads 1 Press and hold upper right hidden switch until the display reads UNITS Release switc...

Page 27: ...idden switch until the display reads UNITS Release switch Continue to press and release switch until the display reads SET READY 2 To adjust the ready temperature press the button to decrease or to in...

Page 28: ...OFF switch located on the front switch panel to exit R SPRY OZ M function and return to the MAIN SCREEN SPRAY OZ M SINGLE BREWERS Thisfunctionallowstheoperatortoviewortoenter the actual flow rate comi...

Page 29: ...IN SCREEN BYPASS OZ M DUAL BREWERS Thisfunctionallowstheoperatortoviewortoenter the actual flow rate coming out of the bypass nozzle This is NOT used to change the actual flow rate but to telltheinter...

Page 30: ...SEC TO FIN ISH The 60 second timer on the display will count down to zero When the counter reaches zero the display will change to ENTER OZ along with a number signifying ounces per minute 6 Measure...

Page 31: ...When the counter reaches zero the display will change to ENTER OZ SINGLE brewers LEFT or RIGHT OZ DUAL brewers along with a number 7 Measure the amount of water in the container and using or adjust t...

Page 32: ...st reset BREW COUNTERS NO YES LEFT X XXX NEXT RESET SINGLE BREWERS DUAL BREWERS RIGHT X XXX NEXT RESET L R X XXX NEXT RESET L R X XXX NEXT X XXX NEXT RESET X XXX NEXT EXIT TO NEXT FUNCTION SCREEN 3 To...

Page 33: ...not correctly situated in the rails If this function is activated and a brew cycle is attempted with the funnel not properly situated the display will read FUNNEL NOT IN PLACE until one is in place 5...

Page 34: ...e MAIN SCREEN Procedure to test switches Thisfunctionallowstheoperatortotesttheopera tion of the individual switches on the front panel 1 Place brew funnel s into rails on the brewer both sides on DUA...

Page 35: ...TANK HEATRS ON NEXT OFF HEATER CONTACTOR ON NEXT OFF BREW VALVE ON NEXT OFF BYPASS ON NEXT OFF FUNNEL LOCK ON NEXT OFF SINGLE BREWERS DUAL BREWERS EXIT TO NEXT FUNCTION SCREEN TEST SWITCHES NO YES NOT...

Page 36: ...and ad messages Factory set default values will replace all previous settings EXIT EXIT REPLACE WILL REPLACE ALL BREW SETTINGS ARE YOU SURE NO YES FACTORY DEFAULTS NO YES ThermoF SoftHeat DONE SEL BRE...

Reviews: