background image

Page 13

MUST GRIND INTO 

FUNNEL FIRST 

(COFFEE NAME) 

SETUP COMPLETE 

BEGIN SETUP OF 

(COFFEE NAME) 

QUIT SETUP? 

YES 

USE LEFT SIDE 

ONLY 

INSERT FUNNEL 

WITH NEW NAME 

REVIEW RECIPES?

NO                 YES

(COFFEE NAME)

NO                  YES

3 BATCHES DONE?

NO                 YES

SET NEW RECIPE?

NO                 YES

2 SEC. 

CYCLES THROUGH

THREE SCREENS 

2 SEC. 

FUNNEL 

CONTAINS NAME 

FUNNEL CONTAINS 

NO NAME 

SETUP BREW VOLUMES, BYPASS,  

PULSE BREW, PREINFUSION, DRIPOUT TIME 

SEE SEPARATE DIAGRAMS 

FOR SETUP INSTRUCTIONS 

FUNNEL DETECTED 

P2299-1

SET NEW RECIPE

Using a Smart Funnel and a G9-2T DBC or MHG 

Grinder:

  This function allows operator to set BREW VOL-

UMES, BYPASS PERCENTAGES, PULSE BREW TIMES 

and DRIP-OUT TIMES for each coffee name preset in 

the grinder's memory.

 

Certain coffee NAMES are stored in the grinder's 

memory. When a particular name of coffee is ground 

into the Smart Funnel, that name and the batch size 

selected are transferred from the grinder to the 

programming chip located in the funnel handle. The 

funnel is then inserted into the brewer's left side 

funnel rails. The sensor coil on the brewer reads the 

information contained in the handle. The name of the 

coffee flavor will then appear on the display. This then 

allows the operator to set BREW VOLUMES, BYPASS 

PERCENTAGES, PULSE BREW TIMES and DRIP-OUT 

TIMES  for that particular coffee NAME. It also allows 

the operator to set other brewing parameters, such 

as BREW TEMPERATURE, READY TEMPERATURE, 

BREW LOCKOUTS, etc. Each coffee NAME can be set 

individually to provide optimum brewing quality.

P2415

BREW OZ.  XX.X

(-)        DONE        (+)

% BYPASS  XX.X

(-)        DONE        (+)

3 BATCHES DONE?

NO                     YES

PROGRAMMING THE BREWER (cont.)

DUAL

BREWERS

only

Procedure for Setting the Recipe:

NOTE: Before beginning setup, place a server beneath 

the brew funnel (left side on DUAL brewers).

1.  Insert the funnel into the grinder and select a batch 

size to grind. It is not necessary to have coffee 

beans in the hopper(s) in order to program the 

brewer. The coffee name is pre-selected and stored 

in the grinder's memory (for side being ground 

on DUAL brewers).

2.  Press the  GRIND switch. When the grinder stops 

grinding, remove the funnel.

3.  On the brewer, press and hold the (®) switch until 

the display reads UNITS. Release the switch, then 

press switch again until display reads SET NEW 

RECIPE.

4.  Press and release YES. The display should read 

INSERT FUNNEL WITH NEW NAME, then USE LEFT 

SIDE ONLY on DUAL brewers only, and finally, QUIT 

SETUP? These displays will repeatedly cycle.

5.  Insert  the funnel into the rails of the brewer (left 

side on DUAL brewers). The display should read 

the NAME of the coffee that was ground into the 

funnel, along with a NO and YES. If the NAME on 

the display is correct, press YES

6.  If, for some reason, the name of the coffee from 

the grinder did not load properly into the funnel, 

or if a grind has not yet been done, the display will 

read MUST GRIND INTO FUNNEL FIRST. It will be 

necessary to grind another batch following steps 

1 and 2.

7.  If the grind is acknowledged by the brewer, the 

display will read BEGIN SETUP OF (COFFEE NAME)

Then the screen will display BREW OZ. and a batch 

light will be blinking. (Refer to BREW OZ (SETTING 

OR ADJUSTING for description).

41342 080108

Summary of Contents for DUAL SH DBC WITH SMART FUNNEL DUAL068000

Page 1: ...DBC W SMART FUNNEL S N DUAL068000 UP PROGRAMMING MANUAL BUNN O MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD ILLINOIS 62708 3227 PHONE 217 529 6601 FAX 217 529 6644 41342 0000C 4 12 2008 Bunn O...

Page 2: ...ons to this warranty or to make additional warranties that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied...

Page 3: ...30 Calibrate Sprayhead Flow 30 Calibrate Bypass Flow 31 Brew Counters View Reset 32 Funnel Detect 33 Service Tools 33 Test Outputs Components 33 Test Switches 34 Test Frequency 34 Factory Defaults Re...

Page 4: ...into the funnel and allows for the brewer to automatically set itself to what is read from the funnel handle LAST ON TIME During a pulse brew this is the time set for the second on time and each alte...

Page 5: ...tches are used There are five of these switches that will be used for the setup of the brewer 1 2 3 4 5 1 symbol upper right of the BUNN logo This is used to access the programming mode and is also us...

Page 6: ...s function screen and return to the MAIN SCREEN on the display PROGRAMMING THE BREWER The programming of the brewer is divided into two levels There is one function in Level 1 All other functions are...

Page 7: ...REINFUSION TIMES and DRIP OUT TIMES METHOD 3 Not using a Smart Funnel and or a G9 2T DBC or MHG Grinder This allows the operator to enter ONE set of brew ing parameters for each side on DUAL brewers i...

Page 8: ...CIPE COPY SETTINGS NO YES LEFT RIGHT NO YES Continue to D Cycles thru left side program constants Continue to E FULL 1 2 1 4 SET ALL 3 BATCHES both sides for DUAL brewers ARE YOU SURE NO YES 3 BATCHES...

Page 9: ...ES DONE NO YES 1st OFF LAST X XX X XX X XX TRANSFER COMPLETE ENABLE ADS NO DONE YES SET TEMP 200 F DONE SET READY 195 F DONE 0 REFILL 155 DONE L SPRY OZ M XX X DONE R SPRY OZ M XX X DONE Continue to F...

Page 10: ...N NEXT OFF RIGHT BREW VALVE ON NEXT OFF RIGHT BYPASS ON NEXT OFF RIGHT FUNEL LOCK ON NEXT OFF REFILL VALVE ON NEXT OFF HEATER CONTACTOR ON NEXT OFF SPRAY HEAD CAL NO YES BYPASS CAL NO YES CONTAINER RD...

Page 11: ...onstoredelsewhere so that the machine can be reprogrammed Procedure for modifying units of measure 1 Press and hold upper right hidden switch until the display reads UNITS Release switch Press and rel...

Page 12: ...6 If YES was selected the display should now read X X HRS IDLE This screen allows the opera tor to set the amount of time the brewer is not in use before nap mode engages Using and adjust the idle ti...

Page 13: ...ndividually to provide optimum brewing quality P2415 BREW OZ XX X DONE BYPASS XX X DONE 3 BATCHES DONE NO YES PROGRAMMING THE BREWER cont DUAL BREWERS only Procedure for Setting the Recipe NOTE Before...

Page 14: ...METHOD 17 If setting pulse brew by MANUAL METHOD en tering known times press MANUAL then NEXT and proceed with the setup instructions for SET PULSE BREW MANUAL METHOD SET DRIP TIME Refer to SET DRIP...

Page 15: ...ion the RECIPE CARD vertically so that the top end of the CHIP is beneath the left side funnel sensing coil 3 AfterashortpausethedisplaywillreadCARDCON TAINS RECIPE FOR then will change to COFFEE NAME...

Page 16: ...rwillperform in the same capacity as a standard Bunn Single Dual Brewer The instructions for programming the NO NAME settings are on the following pages The same steps are followed for setting the rec...

Page 17: ...all the brew settings for that particular coffeename Whenfinished thedisplaywillreturn to the coffee name just viewed 4 To see settings again press SHOW To advance to the next coffee name press NEXT 5...

Page 18: ...essanotherbatchsizeandrepeat step 5 for that size for each batch size to be modi fied Continue setting all batch sizes 7 When finished setting all batch sizes press and release DONE The display should...

Page 19: ...l be blinking Press and release the batch size to be modified 7 Using and set the amount of bypass water percentage to be dispensed around the grounds for that particular batch size 8 Whenfinished pre...

Page 20: ...LTERNATES UNTIL BREW CYCLE IS COMPLETED PRE INFUSION REMAINING ON ON TIME OFF TIME OFF TIME OFF TIME OFF TIME ON TIME ON TIME Modifying pulse brew Range 1st on time off to 4 minutes Off time off to 4...

Page 21: ...ME MODIFY SHOW NEXT THAT WAS THE LAST RECIPE WHEN THE LAST COFFEE NAME IN BREWER S MEMORY IS DISPLAYED PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ ADVANCES TO ALL OTHER COFFEE NAMES PROGRAM...

Page 22: ...the indicator light Repeat step 2 for each batch size to be set 4 When finished setting all batch sizes press done This will display the 1st OFF and LAST times for 5 seconds then advance to 3 BATCHES...

Page 23: ...aywillshow thethreetimesjustenteredforthatbatchsize After a 5 second delay the display will read 3 BATCHES DONE 8 If other batch sizes need to be modified press NO 9 Press a different batch size and r...

Page 24: ...A batch light should also be blinking 10 Using the and set the amount of time from when the brew solenoid shuts off to when drip out occurs for that batch size NOTE Set to OFF to prevent funnel locks...

Page 25: ...leasetheswitch Con tinue to press and release switch until the display reads COPY SETTINGS ASSIGN RECIPES This function allows for assigning a coffee name other than NO NAME to the BREW switch Procedu...

Page 26: ...ewer with an AD CARD This message will be displayed when the brewer is not in use Procedure to Enable Disable Ads 1 Press and hold upper right hidden switch until the display reads UNITS Release switc...

Page 27: ...idden switch until the display reads UNITS Release switch Continue to press and release switch until the display reads SET READY 2 To adjust the ready temperature press the button to decrease or to in...

Page 28: ...OFF switch located on the front switch panel to exit R SPRY OZ M function and return to the MAIN SCREEN SPRAY OZ M SINGLE BREWERS Thisfunctionallowstheoperatortoviewortoenter the actual flow rate comi...

Page 29: ...IN SCREEN BYPASS OZ M DUAL BREWERS Thisfunctionallowstheoperatortoviewortoenter the actual flow rate coming out of the bypass nozzle This is NOT used to change the actual flow rate but to telltheinter...

Page 30: ...SEC TO FIN ISH The 60 second timer on the display will count down to zero When the counter reaches zero the display will change to ENTER OZ along with a number signifying ounces per minute 6 Measure...

Page 31: ...When the counter reaches zero the display will change to ENTER OZ SINGLE brewers LEFT or RIGHT OZ DUAL brewers along with a number 7 Measure the amount of water in the container and using or adjust t...

Page 32: ...st reset BREW COUNTERS NO YES LEFT X XXX NEXT RESET SINGLE BREWERS DUAL BREWERS RIGHT X XXX NEXT RESET L R X XXX NEXT RESET L R X XXX NEXT X XXX NEXT RESET X XXX NEXT EXIT TO NEXT FUNCTION SCREEN 3 To...

Page 33: ...not correctly situated in the rails If this function is activated and a brew cycle is attempted with the funnel not properly situated the display will read FUNNEL NOT IN PLACE until one is in place 5...

Page 34: ...e MAIN SCREEN Procedure to test switches Thisfunctionallowstheoperatortotesttheopera tion of the individual switches on the front panel 1 Place brew funnel s into rails on the brewer both sides on DUA...

Page 35: ...TANK HEATRS ON NEXT OFF HEATER CONTACTOR ON NEXT OFF BREW VALVE ON NEXT OFF BYPASS ON NEXT OFF FUNNEL LOCK ON NEXT OFF SINGLE BREWERS DUAL BREWERS EXIT TO NEXT FUNCTION SCREEN TEST SWITCHES NO YES NOT...

Page 36: ...and ad messages Factory set default values will replace all previous settings EXIT EXIT REPLACE WILL REPLACE ALL BREW SETTINGS ARE YOU SURE NO YES FACTORY DEFAULTS NO YES ThermoF SoftHeat DONE SEL BRE...

Reviews: