background image

TM

NIOSH Appr

o

val Label

9

PA

20 P

o

w

e

red Air-Purifying Respir

ator

This r

espir

ator is appr

o

ved only in the f

o

llo

wing configur

ations:

Bullar

d

Cynthiana, KY 41031 US

A

1-800-827-0423

1

Protection

HE - High Efficiency P

a

rticulate Air Filter f

or Pow

ered Air

-Purifying Respirators

2

Cautions and Limitations

A.  

Not f

o

r use in atmospheres containing less th

an 19.5% o

xygen.

B

.  

Not f

o

r use in atmospheres immediatel

y dangerous to lif

e or health.

C

.  Do not exceed maximum use concentrations established by regulatory

standards.

F.

  Do not use this respirator if airflow is less th

an f

our cfm (115 lpm) f

or tight-

fitting facepieces or six cfm (170 lpm) f

o

r hoods and/or helmets.

I.  

Contains electrical p

a

rts which h

ave not been evaluated as an ignition

source in flammable or explosive atmospheres by MSHA/NIO

SH.

J.

  F

ailure to properl

y use and maintain this product could result in death or

serious injury

.

L.  F

o

llow the manufacturer

’s instructions f

or ch

anging cartridges and/or filters.

M.  All approved respirators sh

all be selected, fitted, used, and maintained in accordance with

MSHA, O

SHA, and other applicable regulations.

N.  Never substitute

, modify

, add, or omit p

a

rts. Use onl

y exact replacement p

arts in the

configuration as specified by the manufacturer

.

O

.  Ref

e

r to users instructions, and/or maintenance manuals f

or inf

ormation on use and

maintenance of these respirators.

P.

 

NIO

SH does not evaluate respirators f

o

r use as surgical masks.

PA20 Appr

o

val Label

AL

TERN

A

T

E

BREA

THING

TUBE

AL

TERN

AT

E

BLOWER

UNIT

AL

TERN

A

T

E

BEL

T

A

CCESSORIES

CA

UTIONS

AND

LIMIT

A

T

IONS

2

ABCFIJLMNOP

FIL

TER

FLOW

INDICA

TOR

AL

TERN

A

T

E

HOOD

ASSEMBLIES

TC#

PROTECTION

1

MODEL

PA20

SERIES 

RESPIR

A

TOR COMPONENTS

AL

TERN

A

T

E

SUSPENSION/

HARD HA

T

21C-0765

HE

PA20

X

X
XX

X

XX

XX

X

X

X

X

X   X   X   X  

X

X

 

X

X

 

X   X 

X   X

X

X  

X  

X

X

   X   X 

20TJN

20TICN

20SICN

20TICSN

20TICH

20SICH

20TPN

20TPCN

20LFM

20LFL

20TG

20RT

3000

3000R

5100

5100R

PA1BT

PA

1BTXS

PA

20LFBT

PA20LFBTXS

PA1BU

PA2BU

PA1FG

PA1AFI

PA1SB

PA1DB

PA1STC

PA1SMC

PA2STC

PA2

MC

PA1EB

PA1DEB

20NC

ES42

20LCL

20LC

Summary of Contents for PA1

Page 1: ... Use strictly in accordance with instructions labels and limitations pertaining to the PA20 respirator 1 The PA20 respirator does not supply oxygen Use only in adequately ventilated areas containing at least 19 5 oxygen 2 Do not use when concentrations of contaminants are immediately dangerous to life or health 3 Do not use these respirators for respiratory protection during abrasive blasting 4 Do...

Page 2: ...4 The Battery Charger Both standard and quick chargers are available The high efficiency air purifying element must be mounted inside the blower body The blower unit draws in contaminated air through the filter The filtered air is blown into the wearer s hood through the breathing tube A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior to us...

Page 3: ...arger follow these important guidelines These guidelines also apply to blower units that have been in storage for extended periods of time For new blower units or blower units that have been in storage for extended periods of time follow the directions above under Battery Pack and when the light begins to flash on the Quick Charger do the following Unplug the charger power cord Wait 15 seconds Plu...

Page 4: ...ball in the Airflow Indicator should be observed If any part of the ball is below the PASS LINE on the Airflow Indicator check for Clogged or damaged air purifying filter element See Replacing the PA1FG High Efficiency Filter on the next page for filter mounting instructions Low battery charge or battery malfunction Blower malfunction If the ball is completely above the PASS LINE on the Airflow In...

Page 5: ...the exposed filter pleat Hold the filter only by its edges Check that the filter has a filter gasket and that it is positioned flat behind the filter lip NOTE Always use a new filter gasket when refitting or changing a filter Unclip the blower latches and remove the back cover and belt assembly from the blower unit see Figure 4 Check that the mating faces of blower unit body and the back cover are...

Page 6: ...e fit as required at this time to ensure a comfortable and stable fit See the CC20 PA20 Series Tychem Hood User Manual PA1BU Low Battery Alarm The PA1BU Blower unit is fitted with a Low Battery Alarm This device will activate if the battery power is below acceptable levels The device is indicating that insufficient airflow is imminent The user should do the following Leave the hazard area remove t...

Page 7: ...ection and could result in death or serious injury Consult your local safety professional if you suspect that contaminant has entered the breathing tube When cleaning the equipment do the following Ensure water does not enter filter Replace wet filter DO NOT use gasoline organic based solvents or chlorinated degreasing fluids such as trichloroethylene as they will cause damage DO NOT immerse the e...

Page 8: ...charger for PA2BU Replacement Filter Gasket PA1FG3 Filter gasket assembly 3 per box PA1FGBP Filter gasket assembly 36 per box Replacement Parts and Accessories PA1SB Standard belt PA1DB Decon belt PA1EB Extension belt kit PA1DEB Extension decon belt kit PA1LSK Blower latch and screw kit 4 latches 16 screws PA1AFI Air Flow Indicator PA1BU PA1 Blower housing unit motor and impeller PA2BU PA2 Blower ...

Page 9: ...cturer s instructions for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information o...

Page 10: ...285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Bullard GmbH Hochkreuzallee 36 53175 Bonn Bad Godesberg Germany Tel 49 228 931933 0 Fax 49 228 931933 50 2003 Bullard All rights reserved It s Your Life and You re Worth It is a trademark of Bullard Tychem is a registered trademark of E I DuPont de Nemours Company ISO 9001 certified Cert i f i e d I S O 9001 ...

Reviews: