PA20 Series Powered Air-Purifying Respirator

PA1/PA2 Blower Assembly User Manual

Powered Air-Purifying Respirator with High Efficiency (HE) Filter – Approval No. TC-21C-0765

PA20 PAPR
Cautions and Limitations

A. Not for use in atmospheres containing less than 19.5%

oxygen.

B. Not for use in atmospheres immediately dangerous to

life or health.

C. Do not exceed maximum use concentrations established

by regulatory standards.

F. Do not use respirator if airflow is less than four cfm

(115 lpm) for tight fitting face pieces or six cfm
(170 lpm) for hoods and/or helmets.

I. Contains electrical parts which have not been evaluated

as an ignition source in flammable or explosive
atmospheres by MSHA/NIOSH.

J. Failure to properly use and maintain this product could

result in injury or death.

L. Follow the manufacturer’s user instructions for

changing cartridges and/or filters.

M. All approved respirators shall be selected, fitted, used

and maintained in accordance with MSHA, OSHA and
other applicable regulations.

N. Never substitute, modify, add or omit parts. Use only

exact replacement parts in the configuration as
specified by the manufacturer.

O. Refer to User’s Instructions, and/or maintenance

manuals for information on use and maintenance of
these respirators.

P. NIOSH does not evaluate respirators for use as surgical

masks.

Use strictly in accordance with instructions, labels and
limitations pertaining to the PA20 respirator.

1. The PA20 respirator does not supply oxygen. Use only

in adequately ventilated areas containing at least
19.5% oxygen.

2. Do not use when concentrations of contaminants are

immediately dangerous to life or health. 

3. Do not use these respirators for respiratory

protection during abrasive blasting.

4. Do not use in circumstances where the airborne

concentration level of contaminant exceeds maximum
use concentration for this type of respirator as
established by regulatory standards.

5. Leave area immediately if:

• Breathing becomes difficult
• Dizziness or other distress occurs
• You taste or smell the contaminant
• Unit becomes damaged
• Battery alarm sounds

6. This apparatus must not be worn with the blower unit

switched off. If the blower switched off, a rapid build-
up of carbon dioxide and depletion of oxygen may
occur, which could result in death or serious injury.

7. Never alter or modify this respirator. Use only NIOSH

approved PA20 components and replacement parts
for this respirator.

Failure to follow these warnings could result in death or
serious injury.

WARNING

Cautions and Limitations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Principle of Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Battery Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Pre-Operational Inspection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Mounting the Breathing Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Checking Air Flow  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

High Efficiency Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Donning the Blower  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Low Battery Alarm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Cleaning and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

NIOSH Approval Label  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Table of Contents

Cautions and Limitations

1

Summary of Contents for PA1

Page 1: ... Use strictly in accordance with instructions labels and limitations pertaining to the PA20 respirator 1 The PA20 respirator does not supply oxygen Use only in adequately ventilated areas containing at least 19 5 oxygen 2 Do not use when concentrations of contaminants are immediately dangerous to life or health 3 Do not use these respirators for respiratory protection during abrasive blasting 4 Do...

Page 2: ...4 The Battery Charger Both standard and quick chargers are available The high efficiency air purifying element must be mounted inside the blower body The blower unit draws in contaminated air through the filter The filtered air is blown into the wearer s hood through the breathing tube A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior to us...

Page 3: ...arger follow these important guidelines These guidelines also apply to blower units that have been in storage for extended periods of time For new blower units or blower units that have been in storage for extended periods of time follow the directions above under Battery Pack and when the light begins to flash on the Quick Charger do the following Unplug the charger power cord Wait 15 seconds Plu...

Page 4: ...ball in the Airflow Indicator should be observed If any part of the ball is below the PASS LINE on the Airflow Indicator check for Clogged or damaged air purifying filter element See Replacing the PA1FG High Efficiency Filter on the next page for filter mounting instructions Low battery charge or battery malfunction Blower malfunction If the ball is completely above the PASS LINE on the Airflow In...

Page 5: ...the exposed filter pleat Hold the filter only by its edges Check that the filter has a filter gasket and that it is positioned flat behind the filter lip NOTE Always use a new filter gasket when refitting or changing a filter Unclip the blower latches and remove the back cover and belt assembly from the blower unit see Figure 4 Check that the mating faces of blower unit body and the back cover are...

Page 6: ...e fit as required at this time to ensure a comfortable and stable fit See the CC20 PA20 Series Tychem Hood User Manual PA1BU Low Battery Alarm The PA1BU Blower unit is fitted with a Low Battery Alarm This device will activate if the battery power is below acceptable levels The device is indicating that insufficient airflow is imminent The user should do the following Leave the hazard area remove t...

Page 7: ...ection and could result in death or serious injury Consult your local safety professional if you suspect that contaminant has entered the breathing tube When cleaning the equipment do the following Ensure water does not enter filter Replace wet filter DO NOT use gasoline organic based solvents or chlorinated degreasing fluids such as trichloroethylene as they will cause damage DO NOT immerse the e...

Page 8: ...charger for PA2BU Replacement Filter Gasket PA1FG3 Filter gasket assembly 3 per box PA1FGBP Filter gasket assembly 36 per box Replacement Parts and Accessories PA1SB Standard belt PA1DB Decon belt PA1EB Extension belt kit PA1DEB Extension decon belt kit PA1LSK Blower latch and screw kit 4 latches 16 screws PA1AFI Air Flow Indicator PA1BU PA1 Blower housing unit motor and impeller PA2BU PA2 Blower ...

Page 9: ...cturer s instructions for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information o...

Page 10: ...285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Bullard GmbH Hochkreuzallee 36 53175 Bonn Bad Godesberg Germany Tel 49 228 931933 0 Fax 49 228 931933 50 2003 Bullard All rights reserved It s Your Life and You re Worth It is a trademark of Bullard Tychem is a registered trademark of E I DuPont de Nemours Company ISO 9001 certified Cert i f i e d I S O 9001 ...