background image

Free-Air® Pumps 

User Manual

5

Pump P

erf

ormance

www.bullard.com

Electric Motor Specifications: 

 

EDP30 and EDP50

ENClOSURE:

Open, Drip-proof

ClASS:

Natl. Elec. Code:

Class B

Design L

Code K

H.P.

Five

PHASE:

Single

CYClES:

60

WIRING:

208-230 volts as shipped, with 8 foot cord and three 

wire, 30 amp plug (NEMA L6-30) and manual starter

F.l. CURRENT

DRAW:

24.0 Amps at 230 Volts, 

25.5 Amps at 208 Volts

SERVICE FACTOR:

1.15

PROTECTOR:

Internal Thermal Overload in Motor Starter

 

 

Pump Performance Specifications: 

 

EDP30

EDP50

PUMP DESIGN:

Rotary Carbon

Vane (4 vanes)

Rotary Carbon

Vane (4 vanes)

MAXIMUM AIR PRESSURE:

30 psig

15 psig

AIR FlOW:

30 cfm at 10 psig

50 cfm at 10 psig

PRESSURE RElIEF VAlVES:

Adjustable, Pre-Set to open at 34 psig

when adjusted fully closed

Adjustable, Pre-Set to open at 15-17 

psig when adjusted fully closed

PRESSURE GAUGES:

Dry, 0-30 psig on Pod,

0-30 on Pump Manifold

Dry, 0-15 psig on Pods,

0-30 on Pump Manifold

INlET FIlTERS:

Medium Efficiency, Paper-Type

Medium Efficiency, Paper-Type

OUTlET FIlTERS:

CARBOFINE

CARBOFINE

TIRE PRESSURE:

50 psig Maximum

50 psig Maximum

DIMENSIONS:
Width:

26 Inches

26 Inches

length:

38 Inches

38 Inches

Height:

32 Inches

32 Inches

WEIGHT:

292 Lbs.

292 Lbs.

 WARNING

Proper Wiring in accordance with local and national electric codes is 

the responsibility of the user.

Summary of Contents for EDP30

Page 1: ...require expensive carbon monoxide monitors high temperature alarms or airline filters No calibration is required Read all instructions before using your Free Air pump This manual provides detailed in...

Page 2: ...tact the respirator manufacturer or Bullard s Customer Service Department at 877 BULLARD or 1 859 234 6616 3 Supplied air respirators used with this pump MUST NOT be worn in any atmosphere immediately...

Page 3: ...EDP30 PUMP Pump s Output Air Pressure psig Pump s Output Air Volume cfm Maximum Recommended Mask Respirators Maximum Recommended Hood Respirators Motor Amp Load 5 32 Six Four 16 10 30 Six Four 18 15...

Page 4: ...pod s If V60 extension hose IS NOT required go to instruction 3 a Attach the V60 extension hose to the pump s manifold If extending only one pod connect the V60 hose to the manifold Kamlok coupler tha...

Page 5: ...ry Carbon Vane 4 vanes MAXIMUM AIR PRESSURE 30 psig 15 psig AIR FLOW 30 cfm at 10 psig 50 cfm at 10 psig PRESSURE RELIEF VALVES Adjustable Pre Set to open at 34 psig when adjusted fully closed Adjusta...

Page 6: ...f the respirator system being used to the quick disconnect coupler s or the pod s Figure 6 NOTE If your respirator s air supply hose approved by NIOSH as part of the respirator system being used will...

Page 7: ...respirators NOTE If the pod s are attached directly to the pump manifold the pressure gauges should always read within 5 of each other If the gauge on the manifold reads substantially higher than the...

Page 8: ...p with the gasket g Insert four 4 new filter cartridges in the seats and reassemble the caps and wing nuts to hold the cartridges in place h Reassemble the pod Tighten the wing nuts and bolts together...

Page 9: ...ough the respirator s air supply hose until it reaches ambient air temperature 2 If pressure relief valves are set too high reset to a lower pressure Be sure the outlet pressure remains in the approve...

Page 10: ...Gauge 0 15 psig S19683 Pressure Gauge 0 30 psig S19688 Pressure Gauge 0 60 psig S2084 Drive Belt Matched Pair EDP30 S2085 Drive Belt Matched Pair EDP50 S2089 Kamlok Adapter Male Pod S2090 Kamlok Coup...

Page 11: ...to factory inspection In warranty product of current design will be subjected to a rehandling charge less freight originally allowed All material must be shipped with transportation charges prepaid B...

Page 12: ...e outlet filter cartridge is multi layered with 40 micron size particles of activated carbon a sorbent bed with an exposed carbon surface of more than 15 000 square feet Vapor removal efficiency 90 95...