 WARNING

2

W

arnings

READ ALL INSTRUCTIONS IN THIS MANUAL BEFORE USING FREE-AIR

®

 PUMP MODELS EDP30 OR EDP50.

FAILURE TO OPERATE THESE PUMPS IN ACCORDANCE WITH THE INSTRUCTIONS CONTAINED IN THIS MANUAL MAY RESULT IN DEATH OR 

SERIOUS INJURY TO THE RESPIRATOR WEARER.

1. Place the pump’s inlet filters in a clean breathable air location at all times. The pump WILL NOT remove carbon monoxide, toxic gases or 

other contaminants from the incoming air it transfers to the respirator wearer.

See the BREATHING AIR REQUIREMENTS section on page 4 for specific details on breathing air quality.

2. This pump will supply the required volume of air (6-15 cfm for hoods or 4-15 cfm for tight fitting mask) to low pressure supplied air 

respirators. The respirators must be approved by MSHA/NIOSH to operate at 30 psig or less if using an EDP30 pump, or 15 psig or less if 
using an EDP50 pump.

Be sure the pump’s outlet pressure, measured by the pressure gauge on the air supply hose’s quick-disconnect coupler pod, is maintained 
above the minimum pressure setting required by the respirator manufacturer.

To verify your respirator can be used with this pump refer to:

a) The Pump Performance Table on page 3 for the maximum output air pressure (psig) of the pump model you are using. 

b) The section in the respirator’s instruction manual for the MSHA/NIOSH approved pressure range and permissible air supply hose 

lengths.

If you have any questions about whether or not your respirator is compatible with this pump, contact the respirator manufacturer or 
Bullard’s Customer Service Department at 877-BULLARD or 1-859-234-6616.

3. Supplied air respirators used with this pump MUST NOT be worn in any atmosphere immediately dangerous to life or health or from which 

the wearer cannot escape without the use of the respirator.

Supplied air respirators used with this pump MUST NOT be worn in oxygen deficient or unknown atmospheres.

4. When connecting respirators to the Free-Air pump, use only the air supply hose and couplers required by the respirator manufacturer and 

approved by MSHA/NIOSH.
Use of non approved hoses or couplers will VOID the respirator’s MSHA/NIOSH approval and could reduce the air flow to the respirator, 

resulting in possible death or serious injury to the respirator wearer.

5. DO NOT modify or alter the pump in any manner. Use only approved Bullard Free-Air pump components and replacement parts on this 

pump.
Failure to use approved Bullard components and replacement parts invalidates all Bullard warranties, and may result in death or serious 

injury to the respirator wearer.

6. If you have any questions concerning the use of the pump or your respirator, or you are not sure the inlet filters are in a breathable air 

location, ask your supervisor.
All instructions for the use and care of this product must be supplied to you by your employer as recommended by the manufacturer and 
as required by Federal Law (29 CFR 1910.134).

For technical assistance or additional copies of this manual, call Bullard Customer Service or go to www.Bullard.com to download a copy.

Bullard

 

1898 Safety Way 
Cynthiana, KY 41031-9303 
Toll-free: 877-BULLARD (285-5273) 
Phone: 859-234-6616
Web: www.bullard.com
Email: [email protected]

Summary of Contents for EDP30

Page 1: ...require expensive carbon monoxide monitors high temperature alarms or airline filters No calibration is required Read all instructions before using your Free Air pump This manual provides detailed in...

Page 2: ...tact the respirator manufacturer or Bullard s Customer Service Department at 877 BULLARD or 1 859 234 6616 3 Supplied air respirators used with this pump MUST NOT be worn in any atmosphere immediately...

Page 3: ...EDP30 PUMP Pump s Output Air Pressure psig Pump s Output Air Volume cfm Maximum Recommended Mask Respirators Maximum Recommended Hood Respirators Motor Amp Load 5 32 Six Four 16 10 30 Six Four 18 15...

Page 4: ...pod s If V60 extension hose IS NOT required go to instruction 3 a Attach the V60 extension hose to the pump s manifold If extending only one pod connect the V60 hose to the manifold Kamlok coupler tha...

Page 5: ...ry Carbon Vane 4 vanes MAXIMUM AIR PRESSURE 30 psig 15 psig AIR FLOW 30 cfm at 10 psig 50 cfm at 10 psig PRESSURE RELIEF VALVES Adjustable Pre Set to open at 34 psig when adjusted fully closed Adjusta...

Page 6: ...f the respirator system being used to the quick disconnect coupler s or the pod s Figure 6 NOTE If your respirator s air supply hose approved by NIOSH as part of the respirator system being used will...

Page 7: ...respirators NOTE If the pod s are attached directly to the pump manifold the pressure gauges should always read within 5 of each other If the gauge on the manifold reads substantially higher than the...

Page 8: ...p with the gasket g Insert four 4 new filter cartridges in the seats and reassemble the caps and wing nuts to hold the cartridges in place h Reassemble the pod Tighten the wing nuts and bolts together...

Page 9: ...ough the respirator s air supply hose until it reaches ambient air temperature 2 If pressure relief valves are set too high reset to a lower pressure Be sure the outlet pressure remains in the approve...

Page 10: ...Gauge 0 15 psig S19683 Pressure Gauge 0 30 psig S19688 Pressure Gauge 0 60 psig S2084 Drive Belt Matched Pair EDP30 S2085 Drive Belt Matched Pair EDP50 S2089 Kamlok Adapter Male Pod S2090 Kamlok Coup...

Page 11: ...to factory inspection In warranty product of current design will be subjected to a rehandling charge less freight originally allowed All material must be shipped with transportation charges prepaid B...

Page 12: ...e outlet filter cartridge is multi layered with 40 micron size particles of activated carbon a sorbent bed with an exposed carbon surface of more than 15 000 square feet Vapor removal efficiency 90 95...

Reviews: