background image

BULL CEDOC

357 AVENUE PATTON

B.P.20845

49008 ANGERS CEDEX 01

FRANCE

86 A1 34EM 00

REFERENCE

Summary of Contents for NovaScale Blade 2040 Series

Page 1: ...NovaScale Blade 2040 Series Installation and User s Guide NOVASCALE BLADE REFERENCE 86 A1 34EM 00...

Page 2: ......

Page 3: ...NOVASCALE BLADE NovaScale Blade 2040 Series Installation and User s Guide May 2004 BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 34EM 00 Hardware...

Page 4: ...to use the Ordering Form also provided at the end of this book Trademarks and Acknowledgements We acknowledge the right of proprietors of trademarks mentioned in this book Intel and Itanium are regis...

Page 5: ...ns ce docu ment avant de suivre toute instruction Consultez le manuel NovaScale Blade Series Boards and Chassis Safety Information Wichtige Sicherhetshinweise Lesen Sie zun chts s mtliche Warn und Sic...

Page 6: ...ardous position Place removed covers and other parts in a safe place away from all personnel while you are servicing the machine Keep your tool case away from walk areas so that other people will not...

Page 7: ...rforming a mechanical inspection Working near power supplies Removing or installing main units Before you start to work on the machine unplug the power cord If you cannot unplug it ask the customer to...

Page 8: ...trostatic discharge ESD ESD damage can occur when there is a difference in charge between objects Protect against ESD damage by equalizing the charge so that the server the part the work mat and the p...

Page 9: ...ts any equipment that will be attached to this product When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or struct...

Page 10: ...he battery as required by local ordinances or regulations CAUTION When laser products such as CD ROMs DVD ROM drives fiber optic devices or transmitters are installed note the following Do not remove...

Page 11: ...the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current...

Page 12: ...nected to the power source Always replace the blade cover before installing the blade Safety compliance USA UL 60950 3rd Edition CSA 22 2 No 60950 Canada cUL certified 3rd Edition CSA 22 2 No 60950 fo...

Page 13: ...ase the user will be required to correct the interference at his her own expense Electromagnetic compatibility ECM USA FCC CFR 47 Part 2 and 15 Verified Class A Limit Canada IC ICES 003 Class A Limit...

Page 14: ...ss A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may...

Page 15: ...nment so that distributors or users pay attention to this point If the product is sold or purchased improperly please exchange this product to what can be used at home Class B device This device compl...

Page 16: ...xiv NovaScale Blade 2040 Installation and User s Guide This page intentionally left blank...

Page 17: ...server 13 Blade server controls and LEDs 14 3 Installing options 19 Installation guidelines 19 System reliability considerations 19 Removing the blade server from the system chassis 19 Opening the bla...

Page 18: ...User s Guide Replacing the CPU board 56 Replacing the I O board 65 6 Installing the operating system 73 Microsoft Windows Server 2003 Enterprise Edition installation instructions 74 Red Hat Linux Ser...

Page 19: ...th the NovaScale Blade 2040 Installation and User s Guide is the CD ROM NovaScale Blade 2040 Resource CD to help you configure hardware install device drivers and install the operating system This Ins...

Page 20: ...in the system chassis write whatever identifying information you want on a label and place it on the system chassis bezel just below the blade server as shown in the following illustration Important D...

Page 21: ...g Guide This publication contains the information to help you solve NovaScale Blade 2040 problems yourself it also contains information for service technicians NovaScale Blade Chassis Installation and...

Page 22: ...rs for auxiliary fabric attach point PCI X internal interface and SERDES external interface Size Height 24 5 cm 9 7 inches Depth 44 6 cm 17 6 inches Width 5 9 cm 2 32 inches Maximum weight 5 4 kg 12 l...

Page 23: ...hese statements indicate situations that can be potentially lethal or extremely hazardous to you A danger statement is placed just before the description of a potentially lethal or extremely hazardous...

Page 24: ...S These RAS features help to ensure the integrity of the data stored on your blade server that your blade server is available when you want to use it and that should a failure occur you can easily dia...

Page 25: ...ents in your blade server You need to remove the blade server from the system chassis and remove the blade server cover to see the components NOTE The illustrations in this document might differ sligh...

Page 26: ...sion unit optional 2 Top cover assembly 3 I O board 4 I O board base mount 5 CPU board 6 Chassis assembly base blade 7 Front bezel 8 Terminator card 9 IDE hard drive 10 IDE hard drive tray 11 IDE conn...

Page 27: ...server from the system chassis open the cover and press the Light Path Diagnostics button to light any error LEDs that were turned on during processing The LEDs will remain lit for a maximum of 25 sec...

Page 28: ...sed 2 Off Password clear 3 Off CMOS clear 4 Off Reserved 5 Off BMC force update TP00453 I H NMI Error LED BMC Error LED Temp Error LED I O Board Error LED Light Path Diagnostics LED Processor Board Er...

Page 29: ...up BIOS page The default position is pins 1 and 2 See the NovaScale Blade 2040 Hardware Maintenance Manual and Troubleshooting Guide on the CD ROM NovaScale Blade 2040 Resource CD for complete details...

Page 30: ...12 NovaScale Blade 2040 Installation and User s Guide...

Page 31: ...y when power is restored if the blade server is configured through the chassis management module to do so You can turn on the blade server remotely by means of the service processor in the chassis man...

Page 32: ...on the blade server again If the operating system stops functioning you can press and hold the power control button for more than 4 seconds to turn off the blade server The management module can turn...

Page 33: ...indicates that a system error has occurred in the blade server Information LED C When this amber LED is lit it indicates that information about a system error for this blade server has been placed in...

Page 34: ...cation with these devices 2 It can take approximately 20 seconds to switch the keyboard video and mouse or the CD ROM drive diskette drive and USB port to the blade server 3 Although the keyboard atta...

Page 35: ...ed behind the control panel door Press this button to manually turn the blade server on or off NOTE This button has effect only if local power control is enabled for the blade server Local power contr...

Page 36: ...18 NovaScale Blade 2040 Installation and User s Guide...

Page 37: ...to disk drives Before you remove a hot swap blade server from the system chassis you must shut down the operating system and turn off the blade server You do not have to shut down the system chassis...

Page 38: ...ds until the drives stop spinning before proceeding to the next step See Blade server controls and LEDs on page 14 for more information about the location of the power control button 2 Open the two re...

Page 39: ...the blade cover before installing the blade Removing the blade server bezel assembly To install certain options you must first remove the blade server bezel assembly The following illustration shows...

Page 40: ...separate bus Some models come with at least one IDE hard disk drive already installed Two IDE drives can be used to implement and manage RAID level 1 under both the Linux and Microsoft Windows operat...

Page 41: ...system chassis See Removing the blade server from the system chassis on page 19 for instructions 3 Carefully lay the blade server on a flat non conductive surface 4 Open the blade server cover See Op...

Page 42: ...erver are 256 MB 512MB 1 GB and 2GB Your blade server supports a minimum of 512 MB and a maximum of 16GB of system memory 3 Install the DIMMs in the following order 4 Both DIMMs in a pair must be the...

Page 43: ...ve surface 4 Open the blade server cover See Opening the blade server cover on page 20 for instructions 5 Locate the DIMM connectors on the system board Determine the connectors into which you will in...

Page 44: ...nal clock frequencies must be identical Notes 1 Thoroughly review the documentation that comes with the microprocessor so that you can determine whether you need to update the blade server BIOS code C...

Page 45: ...ystem has a single dual or quad processor configuration A three processor configuration is NOT supported Locate the appropriate microprocessor socket s on the system board for installing an additional...

Page 46: ...ocessor replacements or upgrades involving existing heat sinks see the instructions listed in Replacing or Upgrading a Microprocessor on page 51 7 Remove the heat sink filler a Loosen the captive scre...

Page 47: ...the microprocessor into the socket Attention Do not use excessive force when pressing the microprocessor into the socket Make sure that the microprocessor is oriented and aligned correctly in the sock...

Page 48: ...l on the heat sink Touching the thermal interface material will contaminate it c Align and place the heat sink A on top of the microprocessor Press down firmly on the heat sink Lower the retention mec...

Page 49: ...the switch modules in switch module bays 3 and 4 on the system chassis are for the same interface For example if you add the Fibre Channel Expansion Card option to your blade server the modules in swi...

Page 50: ...er on page 20 for instructions 5 If an IDE hard disk drive is in IDE connector 2 remove the drive and tray save the screws that secured the tray to the system board otherwise remove the two screws A n...

Page 51: ...all two 3 5 inch hot swap SCSI 1 inch 26 mm slim high hard disk drives in the expansion unit for use by the blade server The SCSI Storage Expansion Unit contains a SCSI controller that supports embedd...

Page 52: ...ade server from the system chassis see Removing the blade server from the system chassis on page 19 for instructions 3 Carefully lay the blade server on a flat non conductive surface Remove the blade...

Page 53: ...nit so that the slots at the rear slide down onto the pins A at the rear of the blade server c Pivot the storage expansion unit closed and press it firmly into place until the cover release latches cl...

Page 54: ...he system chassis With the storage expansion unit installed on your blade server you can install up to two hot swap SCSI hard disk drives in the option and configure them for embedded mirroring RAID l...

Page 55: ...ap hard disk drive in the expansion unit fails you can replace it without turning off the blade server Therefore you have the advantage of continuing to operate your blade server while a hard disk dri...

Page 56: ...anel and pulling it away from the expansion unit 3 Install the hard disk drive B a Ensure that the tray handle C is open that is perpendicular to the drive b Align the drive assembly with the guide ra...

Page 57: ...e the handle A on the drive to the open position perpendicular to the drive and pull the hot swap drive assembly from the bay 5 Within 1 minute install the replacement hard disk drive in the hot swap...

Page 58: ...se of the battery as required by local ordinances or regulations Complete the following steps to replace the battery 1 Review the information in General Safety and Electrical Safety beginning on page...

Page 59: ...the socket under the battery clip b As you slide it under the battery clip press the battery down into the socket 8 Close the blade server cover see Closing the blade server cover on page 44 xxCAUTION...

Page 60: ...you have just plugged the power cords of your system chassis into electrical outlets you will have to wait until the power on LED on the blade server flashes slowly before pressing the power control b...

Page 61: ...he blade chassis Insert the metal clips into the underside of the slots and then rotate the bezel assembly up until it clicks into place NOTE It may be easiest to perform this step by placing the blad...

Page 62: ...on in General Safety and Electrical Safety beginning on page iii and Installation guidelines on page 19 2 If you removed the blade bezel assembly replace it now See Installing the blade server bezel a...

Page 63: ...n guidelines on page 19 and Handling electrostatic discharge sensitive devices on page vi 2 If you have not done so already install any options needed such as disk drives or memory in the blade server...

Page 64: ...D on the blade control panel is lit continuously indicating that the blade server is receiving power and is turned on 9 If desired write identifying information on one of the user labels that comes wi...

Page 65: ...erver with more than one microprocessor your blade server can now operate as an SMP server Therefore you might need to upgrade your operating system to support SMP See Chapter 5 Installing the operati...

Page 66: ...ideo and mouse 3 If you install Microsoft Windows 2000 on the blade server while it is not the current owner of the keyboard video and mouse the first time the blade server requests ownership after th...

Page 67: ...See Chapter 2 Configuring your blade server in the NovaScale Blade 2040 Hardware Maintenance Manual and Troubleshooting Guide for more information about the BIOS Setup Utility program and configuring...

Page 68: ...50 NovaScale Blade 2040 Installation and User s Guide...

Page 69: ...NOTE Read Installation guidelines on page 19 Review the information in General Safety and Electrical Safety beginning on page iii and Installation guidelines on page 19 Read Handling electrostatic di...

Page 70: ...he captive screw A and lift the retention bar B b Lift the heat sink C off of the microprocessor c The heat sink may be difficult to remove from the microprocessor due to the bond formed by the therma...

Page 71: ...extended in the 90 degree position d Center the microprocessor B to be upgraded or replaced over the microprocessor socket e Align the triangle on the corner of the microprocessor with the triangle on...

Page 72: ...g steps to replace thermal grease a Place the heat sink on a clean work surface b Wipe all thermal grease from the bottom of the heat sink c Using the thermal grease syringe dispense the entire 0 02 m...

Page 73: ...einstall the air baffle NOTE CPUs may overheat if the clear plastic air baffle is not installed 13 If you have other options to install or remove do so now otherwise go to Completing the installation...

Page 74: ...ove the blade server from the system chassis see Removing the blade server from the system chassis on page 19 for instructions 3 Remove the blade server cover see Opening the blade server cover on pag...

Page 75: ...at sink retention mechanism bracket Lift the retention mechanism bracket up B Remove the microprocessor heat sink C 8 Pull out and lift up on the microprocessor locking lever A to unlock the microproc...

Page 76: ...to close each retention mechanism bracket before loosening the corresponding captive screws Lift the retention mechanism assembly B out of the blade chassis Disconnect the three I O board flex ribbon...

Page 77: ...its 59 Disconnect the I O board power cable E from its connector on the CPU board 12 Slide the CPU board out of the blade chassis by sliding the CPU board rearward A and then lifting upward B B TP0046...

Page 78: ...lade 2040 Installation and User s Guide 13 Align the new CPU board with the five guide hooks A and two guide pins B on the blade chassis 14 Insert the new CPU board into the blade chassis TP00467 A B...

Page 79: ...he CPU board taking care to line up the cable connector correctly with the CPU board connector Carefully bend each flex ribbon cable around the piano hinge on the I O board Next gently insert each fle...

Page 80: ...ly extended in the 90 degree position Center and align the microprocessor C over the microprocessor socket Make sure that the microprocessor is oriented and aligned correctly in the socket before clos...

Page 81: ...heat sink and tighten the captive mounting screw C Some downward pressure will be required to tighten the screw Do not overtighten the screw 19 Repeat steps 24 through 30 for the remaining microproces...

Page 82: ...Installation and User s Guide 20 Reinstall the clear plastic air baffle NOTE CPUs may overheat if the clear plastic air baffle is not installed 21 Lower the I O board assembly A It should snap into p...

Page 83: ...g the I O board NOTE Review the information in General Safety and Electrical Safety beginning on page iii and Installation guidelines on page 19 Read Handling electrostatic discharge sensitive devices...

Page 84: ...40 Installation and User s Guide 4 Remove the clear plastic air baffle 5 Press the green button A on the right side of the blade chassis to release the I O board assembly Swing I O board assembly B up...

Page 85: ...llowing recommended procedure to disconnect a flex ribbon cable from its I O board connector Use the pull straps and pull evenly so as not to damage the connector Repeat this process for all three fle...

Page 86: ...each of the IDE drive trays Remove the IDE drive tray B NOTE If an I O expansion card is installed in place of an IDE drive then loosen the four screws on the I O expansion card tray 8 Slide I O board...

Page 87: ...e new I O board by inserting the I O board frontwise underneath the rear rollers A on the I O board assembly taking care to align the I O board up with the five guide hooks B and two guide pins C on t...

Page 88: ...ard connector a Carefully bend each flex ribbon cable around the piano hinge on the I O board b Gently insert each flex ribbon cable into its appropriate connector on the I O board taking care to line...

Page 89: ...d 12 Reinstall any IDE drives or daughter cards 13 Reinstall the blade server cover see Closing the blade server cover on page 44 for instructions 14 Reinsert the blade server into the system chassis...

Page 90: ...72 NovaScale Blade 2040 Installation and User s Guide...

Page 91: ...e system chassis uses USB for internal communication with these devices It can take approximately 20 seconds to switch the keyboard video and mouse or the CD ROM drive diskette drive and USB port to t...

Page 92: ...ns the LSI Logic PCI SCS FC device driver into the diskette drive and press Enter Select the LSI Logic PCI SCSI FC MPI Miniport device driver and press Enter Specify any additional CD ROM drives you w...

Page 93: ...Notice that Setup uses the organization name that you specified earlier as a suggested name for the blade server NOTE Passwords are case sensitive Use a combination of uppercase and lowercase letters...

Page 94: ...e CD diskette and USB port Then press the KVM select button to associate that blade server with the keyboard monitor and mouse Insert the RedHat Linux Server CD into the CD ROM drive The blade server...

Page 95: ...xt the installation program will begin This process can not be undone If you have decided not to continue with this installation this is the last point at which you can safely abort the installation p...

Page 96: ...78 NovaScale Blade 2040 Installation and User s Guide...

Page 97: ...ntrol 17 select 15 C components location of 7 major 7 system board 9 configuration updating 47 connectors battery 9 I O expansion option 9 IDE 9 input output 47 memory 9 microprocessor 9 SCSI expansio...

Page 98: ...emory modules 24 installing bezel assembly 42 hot swap drive 37 39 IDE hard disk drives 22 memory module 24 microprocessor 26 options 19 SCSI storage expansion unit 33 integrated functions 4 L LEDs ac...

Page 99: ...battery 39 S SCSI IDs 36 SCSI storage expansion unit device drivers 36 enable or disable 37 setting BIOS code page jumper 11 starting the blade server 13 stopping the blade server 13 system board conn...

Page 100: ...82 NovaScale Blade 2040 Installation and User s Guide...

Page 101: ...TION Your comments will be promptly investigated by qualified technical personnel and action will be taken as required If you require a written reply please include your complete mailing address below...

Page 102: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 103: ......

Page 104: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 34EM 00 REFERENCE...

Reviews: