MAKSİCONDENSE 48-65
Notes
03/2020
163
T
EKNİK EĞİTİM VE DESTEK
Display
Meaning/text
Display values/adjustable values
XXXX
Parameter with code 96 entered
XXX
D.028
Accessory relay 2
(2 in 7 multi-functional module/VR 40)
Circulation pump [1]/
External pump
[2]
/Cyl-
inder charging pump [3]/Extraction hood
[4]/Ext. solenoid valve [5]/
Ext. fault message [6]
Not active:
Solar pump [7]/eBUS remote
control [8]/Legionella protection pump [9]
D.029
Current volume flow
l/min
D.033
Fan speed target value
In rpm
D.034
Fan speed actual value
In rpm
D.035
3-port valve position
Heating mode [0%]/Parallel operation
[50%]/Domestic hot water mode [100%]
D.040
Actual flow temperature value
in °C
D.041
Return temperature actual value
in °C
D.044
Digitised ionisation value
0 to 1020
Good flame < 400
No flame > 800
D.047
Outdoor temperature (with weather-com-
pensated boiler control)
Actual value in °C
D.050
Offset min. speed
0 to 3000 rpm
Unit-dependent factory setting
D.051
Offset max. speed
- 990 to 0 rpm
Unit-dependent factory setting
D.060
Number of safety cut-out switch-off se-
quences
Value
D.061
Number of flame sequence control switch-
off sequences
Value
D.064
Avg. ignition time
In sec.
D.065
Max. ignition time
In sec.
D.067
Remaining anti-cycl. time for heating
In minutes
D.068
Number of first start attempts
Quantity
D.069
Number of second start attempts
Quantity
D.071
Max. Heating target flow temp.
In °C, adjustment range, 40 – 80 °C (
75 °C
)
D.072
Pump overrun after cylinder charging
(warm start for SPACE HEATERW)
In min, adjustment range, 0
– 10 min
(2 min)
D.074
Anti-legionella function (shift-load cylinder)
ON
D.075
Max. cylinder charging time (domestic hot
water cylinder without own control system)
In min, adjustment range, 20
– 90 min
(48 min)
Summary of Contents for Thema Condens AS 48-A
Page 1: ...DEM RD K M MAKS CONDENSE 48 65...
Page 2: ......
Page 5: ...8 4 2 Gas consumption relating to nominal load 191 8 5 System checklist 192...
Page 6: ......
Page 12: ...MAKS CONDENSE 48 65 Notes 01 2018 6 Training 0020260859_00...
Page 28: ...MAKS CONDENSE 48 65 Notes 01 2018 22 Training 0020260859_00...
Page 44: ...MAKS CONDENSE 48 65 Notes 01 2018 38 Training 0020260859_00...
Page 110: ...MAKS CONDENSE 48 65 Notes 01 2018 104 Training 0020260859_00...
Page 122: ...MAKS CONDENSE 48 65 Notes 01 2018 116 Training 0020260859_00...
Page 124: ...MAKS CONDENSE 48 65 Notes 01 2018 118 Training 0020260859_00 C43P C53 C83 C83P C93 C63...
Page 146: ...MAKS CONDENSE 48 65 Notes 01 2018 140 Training 0020260859_00...
Page 156: ...MAKS CONDENSE 48 65 Notes 01 2018 150 Training 0020260859_00 6 4 Regional legislation...
Page 182: ...MAKS CONDENSE 48 65 Notes 01 2018 176 Training 0020260859_00...
Page 193: ...MAKS CONDENSE 48 65 Notes 03 2020 187 TEKN K E T M VE DESTEK...
Page 196: ...MAKS CONDENSE 48 65 Notes 01 2018 190 Training 0020260859_00...