GAS 222.30 Ex2
9 Appendices
9.1 Technical Data
Gas Probe Technical Data
Ambient temperature without accessories:
-20 to +80 °C
Ambient temperature for accessories:
Component
Ambient temperature range
Compressed air valve:
-30 °C < T
amb
< +60 °C
Solenoid valve for pneumatic drive:
-10 °C < T
amb
< +55 °C
Pneumatic drive:
-20 °C < T
amb
< +80 °C
Limit switch:
-25 °C < T
amb
< +60 °C
Terminal box:
-20 °C < T
amb
< +70 °C
Max. gas inlet temperature:
+195 °C (T3)/+130 °C (T4)
Medium temperature (blowback):
Component
Medium temperature range
Compressed air valve:
-10 °C to +80 °C
Solenoid valve for pneumatic drive:
-10 °C to +100 °C
Max. operating pressure
6 bar
Material:
1.4571; ball valve 1.4408
Parts in contact with media:
Seals: PTFE/graphite/1.4404
and see filter
Markings:
ATEX:
II 3G Ex ec mb IIC T3/T4 Gc
IECEx: Ex ec mb IIC T3/T4 Gc
9.2 Terminal Diagram Probe Terminal Box
Blowback solenoid valve
24 VDC/115 VAC/230 VAC
Sample gas solenoid valve
24 VDC/115 VAC/230 VAC
not used
not intrinsically safe
intrinsically safe
ii
19
Bühler Technologies GmbH
BE460064 ◦ 08/2019
Summary of Contents for GAS 222.30 Ex2
Page 23: ...GAS 222 30 Ex2 9 5 Dimensions 21 B hler Technologies GmbH BE460064 08 2019...
Page 24: ...GAS 222 30 Ex2 22 B hler Technologies GmbH BE460064 08 2019...
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 44: ...DE 461099 05 2016 Page 8 9...