GAS 222.30 Ex2
4 Installation and connection
NOTICE
Accessories may limit critical operating parameters of the base unit
Adding accessories may limit critical operating parameters. Ambient temperatures, zone
classifications, explosion groups, temperature classes or chemical resistances of ac-
cessories may vary from the base unit.
Always include all technical data in the operating instructions and data sheets of all
components in the safety assessment.
4.1 Installation site requirements
Sample gas probes are intended for flange mounting.
– Installation site and installation position are determined based on requirements specific to the application.
– If necessary, the connection piece should be slightly tilted toward the centre of the channel.
– The installation site should be protected from the weather.
– In addition, adequate and safe access for installation and future maintenance work should be provided. Particularly follow
the uninstalled size of the probe tube!
If the probe is transported to the installation site in pieces, it will first need to be assembled.
4.2 Installation
DANGER
Danger to life and explosion during installation and maintenance
The unit must not be worked on (assembly, installation, maintenance) in explosive at-
mospheres.
DANGER
Explosion hazard
When used in explosive areas
Flammable gasses and dust could ignite or explode.
Never operate the gas probe outside the specifications. Extracting gases or gas mixtures
which are also explosive in the absence of air is prohibited.
DANGER
Explosion hazard due to flame propagation
Severe injuries and damage to the system
If the process holds a risk of flame propagation, install a flame arrestor.
4.3 Installing the sampling tube (optional)
The sampling tube, if necessary with the fitting extension, must be screwed in. The probe is then attached to the mating flange
using the included seal and nuts.
4.4 Installing the Inlet Filter (Optional)
The inlet filter, if necessary with matching extension, must be screwed in. The probe is then attached to the mating flange using
the included seals and screws.
8
Bühler Technologies GmbH
BE460064 ◦ 08/2019
Summary of Contents for GAS 222.30 Ex2
Page 23: ...GAS 222 30 Ex2 9 5 Dimensions 21 B hler Technologies GmbH BE460064 08 2019...
Page 24: ...GAS 222 30 Ex2 22 B hler Technologies GmbH BE460064 08 2019...
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 44: ...DE 461099 05 2016 Page 8 9...