Bedienungs- und Installationsanleitung
Installation- and Operation Instruction
Gasentnahmesonden / Sample Gas Probes
Baureihe / Series 222.xx AMEX
BX460021, 01/2007 Art. Nr. 90 31 137
35
11 List of chemical resistance
Formula
Substance
Conc.
Teflon
®
PTFE
FFKM
Viton
®
FPM
V4A
CH
3
COCH
3
Acetone
1/1
1/1
4/4
1/1
C
6
H
6
Benzene
1/1 1/1
3/3
1/1
CI
2
Chlorine
10%
wet
1/1
1/1
3/0
4/4
CI
2
Chlorine
97%
1/0
1/0
1/1
1/1
C
2
H
6
Ethane
1/0 1/0
1/0
2/0
C
2
H
5
OH Ethanol
50%
1/1
1/1 2/2 1/0
C
2
H
4
Ethen
1/0 1/0
1/0
1/0
C
2
H
2
Ethin
1/0 1/0
2/0
1/0
C
6
H
5
C
2
H
5
Ethylbenzol
1/0
1/0
2/0
1/0
HF Hydrofluoric
acid
1/0
2/0
4/0
3/4
CO
2
Carbon dioxide
1/1
1/0
1/1
1/1
CO Carbon
monoxide
1/0
1/0
1/0
1/1
CH
4
Methane
tech.
pure
1/1
1/0
1/1
1/1
CH
3
OH Methanol
1/1 1/1 3/4 1/1
CH
3
CI
2
Methylenchloride
1/0 1/0 3/0 1/1
H
3
PO
4
Phosphoric
acid
1-5% 1/1 1/1 1/1
1/1
H
3
PO
4
Phosphoric
acid
30% 1/1 1/1 1/1
1/1
C
3
H
8
Propane
gaseous
1/1 1/0
1/0
1/0
C
3
H
6
O Propenoxide
1/0 2/0 4/0 1/0
HNO
3
Nitric acid
1-10%
1/1
1/0
1/1
1/1
HNO
3
Nitric acid
50%
1/1
1/0
1/0
1/2
HCI Hydrochloric
acid 1-5% 1/1 1/1
1/1
2/4
HCI Hydrochloric
acid 35%
1/1
1/1
1/2
2/4
O
2
Oxygen
1/1
1/1
1/2
1/1
SF
6
Sulphur
hexafluoride
1/0 1/0 2/0 0/0
H
2
SO
4
Sulphuric
acid
1-6% 1/1 1/1 1/1
1/2
H
2
S Hydrosulphide
1/1
1/1
4/4
1/1
N
2
Nitrogen
1/1
1/0
1/1
1/0
C
6
H
5
C
2
H
3
Styrene
1/1
1/0
3/0
1/0
C
6
H
5
CH
3
Toluene
(Methylben-
zene)
1/1
1/1
3/3
1/1
H
2
O Water
1/1
1/1
1/1
1/1
H
2
Hydrogen
1/0
1/0
1/0
1/0
1 = resistant,
2 = practically resistant,
3 = partially resistant,
4 = not resistant,
0 = no data available.
Two values are given for each medium, left number = value at + 20°C (68°F), right number = value at + 50°C (122°F) Temperature.
Important note
The tables headed "Chemical resistance of plastics" and "Properties of plastics materials" have been compiled from information from
various producers of raw materials. The figures relate exclusively to laboratory tests on raw materials. Plastics items made from these
materials are often subject to influences which cannot be detected in a laboratory test (temperature, pressure, stresses in the material,
chemical substances, design features, etc.). For these reasons the figures quoted can serve only as a guideline. In case of doubt we
strongly recommend that a test be carried out. No legal claims can be derived from these figures and we disclaim all liability. The
chemical and mechanical resistance of a product does not suffice for the assessment of its suitability for use, for example legislation
on flammable liquids (explosion protection) is to be taken into particular consideration.
Chemical resistance for other substance on request.