Errors and Information
The LCD panel on the TeraStation displays the messages below when errors occur.
LCD Message
Description
SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are clogging the fan. If any foreign
objects or dust are found, use a pair of tweezers, air duster, or other tool
to remove them.
If the error is displayed again, contact Buffalo technical support for
assistance.
SYSTEM Error E12
Cooling Failure
System temperature has exceeded the maximum safe value. Do not place
objects in the area around the TeraStation. Install the TeraStation in a cool
location.
HDx Error E16
HDx Not Found
Unable to find hard drive X. Hard drive X may be disconnected or may
have failed. Reinstall the hard drive.
HDx Broken E30
Replace the Disk
The number X hard disk may have failed, or the number x hard disk may
be disconnected. Replace the hard disk.
SYSTEM I10
TOO HOT!
The system temperature may have exceeded the safeguard value.
Do not place objects in the area around the TeraStation. Install the
TeraStation in a cool location.
OperationModeI12
Degraded Mode
Operating in degraded mode.
RAID I18
xDrive Rebuilding
Rebuilding drive X in the array.
Note:
Transfer speeds are slower during the rebuild process.
Replication I33
ReplicationFailure
An error occurred during replication. Click
Sync
in Backup & Replication
Settings to attempt replication again.
New Firmware I52
Available
A new firmware version has been released. Update the firmware.
BackupTaskx I54
Backup Failure
A backup job has failed. Make sure that the backup job is cofigured
correctly, and that the NAS is on and not in standby mode. If the backup
job still fails, check the status of NAS, network, and backup source
destination. Also, check the backup log to see if any errors were recorded.