Installing flat roof and wall mounting supports
5
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
20
5.2
Clearances between the collector
braces when using loading trays
(accessory)
The distances between the collector braces (midd-
le/middle, in mm) depend on:
—
the collector version (portrait, landscape)
—
and the maximum wind or snow loads.
For portrait installation, an auxiliary brace must be erec-
ted for the 4th, 7th and 10th collectors (Fig. 23,
Item 1
).
5.2.1 Basic version
The basic version can be used for the following loads:
—
Building height max. 20 m (installation height)
—
max. 2.0 kN/m² wind or snow load
Tab. 7
Distances between auxiliary braces
USER NOTE
Strictly observe the clearances between
the collector braces so that the profile rails
can be installed.
Number of
collectors
Dim. A
Dim. B
Dimension C
4
381 mm
-
-
5
381 mm
-
-
6
571 mm
-
-
7
571 mm
381 mm
-
8
571 mm
381 mm
-
9
571 mm
571 mm
-
10
571 mm
571 mm
381 mm
Fig. 23
Basic version for up to 10 portrait collectors (in mm)
63043970.15-1.SD
63043970.15-1.SD
980
980
980
980
980
980
980
980
980
980
A
B
C
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1
1
1